Docs › OCPP 2.1 › NotifyEVChargingNeeds

NotifyEVChargingNeeds OCPP 2.1

Der Simulator antwortet mit NotSupported, prüft die Nachricht aber gegen das Schema.

Auch in: OCPP 2.0.1

Request

FeldTypEinschränkungen / Beschreibung
evseIdintegerPflichtminimum 1.0
Defines the EVSE and connector to which the EV is connected. EvseId may not be 0.
maxScheduleTuplesintegerminimum 0.0
Contains the maximum elements the EV supports for: + - ISO 15118-2: schedule tuples in SASchedule (both Pmax and Tariff). + - ISO 15118-20: PowerScheduleEntry, PriceRule and PriceLevelScheduleEntries.
chargingNeedsobjectPflicht
chargingNeeds.acChargingParametersobjectEV AC charging parameters for ISO 15118-2
chargingNeeds.acChargingParameters.energyAmountnumberPflichtAmount of energy requested (in Wh). This includes energy required for preconditioning. Relates to: + *ISO 15118-2*: AC_EVChargeParameterType: EAmount + *ISO 15118-20*: Dynamic/Scheduled_SEReqControlModeType: EVTargetEnergyRequest
chargingNeeds.acChargingParameters.evMinCurrentnumberPflichtMinimum current (amps) supported by the electric vehicle (per phase). Relates to: + *ISO 15118-2*: AC_EVChargeParameterType: EVMinCurrent
chargingNeeds.acChargingParameters.evMaxCurrentnumberPflichtMaximum current (amps) supported by the electric vehicle (per phase). Includes cable capacity. Relates to: + *ISO 15118-2*: AC_EVChargeParameterType: EVMaxCurrent
chargingNeeds.acChargingParameters.evMaxVoltagenumberPflichtMaximum voltage supported by the electric vehicle. Relates to: + *ISO 15118-2*: AC_EVChargeParameterType: EVMaxVoltage
chargingNeeds.derChargingParametersobject*(2.1)* DERChargingParametersType is used in ChargingNeedsType during an ISO 15118-20 session for AC_BPT_DER to report the inverter settings related to DER control that were agreed between EVSE and EV. Fields starting with "ev" contain values from the EV. Other fields contain a value that is supported by both EV and EVSE. DERChargingParametersType type is only relevant in case of an ISO 15118-20 AC_BPT_DER/AC_DER charging session. NOTE: All these fields have values greater or equal to zero (i.e. are non-negative)
chargingNeeds.derChargingParameters.evSupportedDERControlarray<string>minItems 1; enum: EnterService, FreqDroop, FreqWatt, FixedPFAbsorb, FixedPFInject, FixedVar, Gradients, HFMustTrip, HFMayTrip, HVMustTrip, HVMomCess, HVMayTrip, LimitMaxDischarge, LFMustTrip, LVMustTrip, LVMomCess, LVMayTrip, PowerMonitoringMustTrip, VoltVar, VoltWatt, WattPF, WattVar
DER control functions supported by EV. + *ISO 15118-20*: DER_BPT_AC_CPDReqEnergyTransferModeType:DERControlFunctions (bitmap)
chargingNeeds.derChargingParameters.evOverExcitedMaxDischargePowernumberRated maximum injected active power by EV, at specified over-excited power factor (overExcitedPowerFactor). + It can also be defined as the rated maximum discharge power at the rated minimum injected reactive power value. This means that if the EV is providing reactive power support, and it is requested to discharge at max power (e.g. to satisfy an EMS request), the EV may override the request and discharge up to overExcitedMaximumDischargePower to meet the minimum reactive power requirements. + Corresponds to the WOvPF attribute in IEC 61850. + *ISO 15118-20*: DER_BPT_AC_CPDReqEnergyTransferModeType: EVOverExcitedMaximumDischargePower
chargingNeeds.derChargingParameters.evOverExcitedPowerFactornumberEV power factor when injecting (over excited) the minimum reactive power. + Corresponds to the OvPF attribute in IEC 61850. + *ISO 15118-20*: DER_BPT_AC_CPDReqEnergyTransferModeType: EVOverExcitedPowerFactor
chargingNeeds.derChargingParameters.evUnderExcitedMaxDischargePowernumberRated maximum injected active power by EV supported at specified under-excited power factor (EVUnderExcitedPowerFactor). + It can also be defined as the rated maximum dischargePower at the rated minimum absorbed reactive power value. This means that if the EV is providing reactive power support, and it is requested to discharge at max power (e.g. to satisfy an EMS request), the EV may override the request and discharge up to underExcitedMaximumDischargePower to meet the minimum reactive power requirements. + This corresponds to the WUnPF attribute in the IEC 61850. + *ISO 15118-20*: DER_BPT_AC_CPDReqEnergyTransferModeType: EVUnderExcitedMaximumDischargePower
chargingNeeds.derChargingParameters.evUnderExcitedPowerFactornumberEV power factor when injecting (under excited) the minimum reactive power. + Corresponds to the OvPF attribute in IEC 61850. + *ISO 15118-20*: DER_BPT_AC_CPDReqEnergyTransferModeType: EVUnderExcitedPowerFactor
chargingNeeds.derChargingParameters.maxApparentPowernumberRated maximum total apparent power, defined by min(EV, EVSE) in va. Corresponds to the VAMaxRtg in IEC 61850. + *ISO 15118-20*: DER_BPT_AC_CPDReqEnergyTransferModeType: EVMaximumApparentPower
chargingNeeds.derChargingParameters.maxChargeApparentPowernumberRated maximum absorbed apparent power, defined by min(EV, EVSE) in va. + This field represents the sum of all phases, unless values are provided for L2 and L3, in which case this field represents phase L1. + Corresponds to the ChaVAMaxRtg in IEC 61850. + *ISO 15118-20*: DER_BPT_AC_CPDReqEnergyTransferModeType: EVMaximumChargeApparentPower
chargingNeeds.derChargingParameters.maxChargeApparentPower_L2numberRated maximum absorbed apparent power on phase L2, defined by min(EV, EVSE) in va. Corresponds to the ChaVAMaxRtg in IEC 61850. + *ISO 15118-20*: DER_BPT_AC_CPDReqEnergyTransferModeType: EVMaximumChargeApparentPower_L2
chargingNeeds.derChargingParameters.maxChargeApparentPower_L3numberRated maximum absorbed apparent power on phase L3, defined by min(EV, EVSE) in va. Corresponds to the ChaVAMaxRtg in IEC 61850. + *ISO 15118-20*: DER_BPT_AC_CPDReqEnergyTransferModeType: EVMaximumChargeApparentPower_L3
chargingNeeds.derChargingParameters.maxDischargeApparentPowernumberRated maximum injected apparent power, defined by min(EV, EVSE) in va. + This field represents the sum of all phases, unless values are provided for L2 and L3, in which case this field represents phase L1. + Corresponds to the DisVAMaxRtg in IEC 61850. + *ISO 15118-20*: DER_BPT_AC_CPDReqEnergyTransferModeType: EVMaximumDischargeApparentPower
chargingNeeds.derChargingParameters.maxDischargeApparentPower_L2numberRated maximum injected apparent power on phase L2, defined by min(EV, EVSE) in va. + Corresponds to the DisVAMaxRtg in IEC 61850. + *ISO 15118-20*: DER_BPT_AC_CPDReqEnergyTransferModeType: EVMaximumDischargeApparentPower_L2
chargingNeeds.derChargingParameters.maxDischargeApparentPower_L3numberRated maximum injected apparent power on phase L3, defined by min(EV, EVSE) in va. + Corresponds to the DisVAMaxRtg in IEC 61850. + *ISO 15118-20*: DER_BPT_AC_CPDReqEnergyTransferModeType: EVMaximumDischargeApparentPower_L3
chargingNeeds.derChargingParameters.maxChargeReactivePowernumberRated maximum absorbed reactive power, defined by min(EV, EVSE), in vars. + This field represents the sum of all phases, unless values are provided for L2 and L3, in which case this field represents phase L1. + Corresponds to the AvarMax attribute in the IEC 61850. + *ISO 15118-20*: DER_BPT_AC_CPDReqEnergyTransferModeType: EVMaximumChargeReactivePower
chargingNeeds.derChargingParameters.maxChargeReactivePower_L2numberRated maximum absorbed reactive power, defined by min(EV, EVSE), in vars on phase L2. + Corresponds to the AvarMax attribute in the IEC 61850. + *ISO 15118-20*: DER_BPT_AC_CPDReqEnergyTransferModeType: EVMaximumChargeReactivePower_L2
chargingNeeds.derChargingParameters.maxChargeReactivePower_L3numberRated maximum absorbed reactive power, defined by min(EV, EVSE), in vars on phase L3. + Corresponds to the AvarMax attribute in the IEC 61850. + *ISO 15118-20*: DER_BPT_AC_CPDReqEnergyTransferModeType: EVMaximumChargeReactivePower_L3
chargingNeeds.derChargingParameters.minChargeReactivePowernumberRated minimum absorbed reactive power, defined by max(EV, EVSE), in vars. + This field represents the sum of all phases, unless values are provided for L2 and L3, in which case this field represents phase L1. + *ISO 15118-20*: DER_BPT_AC_CPDReqEnergyTransferModeType: EVMinimumChargeReactivePower
chargingNeeds.derChargingParameters.minChargeReactivePower_L2numberRated minimum absorbed reactive power, defined by max(EV, EVSE), in vars on phase L2. + *ISO 15118-20*: DER_BPT_AC_CPDReqEnergyTransferModeType: EVMinimumChargeReactivePower_L2
chargingNeeds.derChargingParameters.minChargeReactivePower_L3numberRated minimum absorbed reactive power, defined by max(EV, EVSE), in vars on phase L3. + *ISO 15118-20*: DER_BPT_AC_CPDReqEnergyTransferModeType: EVMinimumChargeReactivePower_L3
chargingNeeds.derChargingParameters.maxDischargeReactivePowernumberRated maximum injected reactive power, defined by min(EV, EVSE), in vars. + This field represents the sum of all phases, unless values are provided for L2 and L3, in which case this field represents phase L1. + Corresponds to the IvarMax attribute in the IEC 61850. + *ISO 15118-20*: DER_BPT_AC_CPDReqEnergyTransferModeType: EVMaximumDischargeReactivePower
chargingNeeds.derChargingParameters.maxDischargeReactivePower_L2numberRated maximum injected reactive power, defined by min(EV, EVSE), in vars on phase L2. + Corresponds to the IvarMax attribute in the IEC 61850. + *ISO 15118-20*: DER_BPT_AC_CPDReqEnergyTransferModeType: EVMaximumDischargeReactivePower_L2
chargingNeeds.derChargingParameters.maxDischargeReactivePower_L3numberRated maximum injected reactive power, defined by min(EV, EVSE), in vars on phase L3. + Corresponds to the IvarMax attribute in the IEC 61850. + *ISO 15118-20*: DER_BPT_AC_CPDReqEnergyTransferModeType: EVMaximumDischargeReactivePower_L3
chargingNeeds.derChargingParameters.minDischargeReactivePowernumberRated minimum injected reactive power, defined by max(EV, EVSE), in vars. + This field represents the sum of all phases, unless values are provided for L2 and L3, in which case this field represents phase L1. + *ISO 15118-20*: DER_BPT_AC_CPDReqEnergyTransferModeType: EVMinimumDischargeReactivePower
chargingNeeds.derChargingParameters.minDischargeReactivePower_L2numberRated minimum injected reactive power, defined by max(EV, EVSE), in var on phase L2. + *ISO 15118-20*: DER_BPT_AC_CPDReqEnergyTransferModeType: EVMinimumDischargeReactivePower_L2
chargingNeeds.derChargingParameters.minDischargeReactivePower_L3numberRated minimum injected reactive power, defined by max(EV, EVSE), in var on phase L3. + *ISO 15118-20*: DER_BPT_AC_CPDReqEnergyTransferModeType: EVMinimumDischargeReactivePower_L3
chargingNeeds.derChargingParameters.nominalVoltagenumberLine voltage supported by EVSE and EV. *ISO 15118-20*: DER_BPT_AC_CPDReqEnergyTransferModeType: EVNominalVoltage
chargingNeeds.derChargingParameters.nominalVoltageOffsetnumberThe nominal AC voltage (rms) offset between the Charging Station's electrical connection point and the utility’s point of common coupling. + *ISO 15118-20*: DER_BPT_AC_CPDReqEnergyTransferModeType: EVNominalVoltageOffset
chargingNeeds.derChargingParameters.maxNominalVoltagenumberMaximum AC rms voltage, as defined by min(EV, EVSE) to operate with. + *ISO 15118-20*: DER_BPT_AC_CPDReqEnergyTransferModeType: EVMaximumNominalVoltage
chargingNeeds.derChargingParameters.minNominalVoltagenumberMinimum AC rms voltage, as defined by max(EV, EVSE) to operate with. + *ISO 15118-20*: DER_BPT_AC_CPDReqEnergyTransferModeType: EVMinimumNominalVoltage
chargingNeeds.derChargingParameters.evInverterManufacturerstringmaxLength 50
Manufacturer of the EV inverter. + *ISO 15118-20*: DER_BPT_AC_CPDReqEnergyTransferModeType: EVInverterManufacturer
chargingNeeds.derChargingParameters.evInverterModelstringmaxLength 50
Model name of the EV inverter. + *ISO 15118-20*: DER_BPT_AC_CPDReqEnergyTransferModeType: EVInverterModel
chargingNeeds.derChargingParameters.evInverterSerialNumberstringmaxLength 50
Serial number of the EV inverter. + *ISO 15118-20*: DER_BPT_AC_CPDReqEnergyTransferModeType: EVInverterSerialNumber
chargingNeeds.derChargingParameters.evInverterSwVersionstringmaxLength 50
Software version of EV inverter. + *ISO 15118-20*: DER_BPT_AC_CPDReqEnergyTransferModeType: EVInverterSwVersion
chargingNeeds.derChargingParameters.evInverterHwVersionstringmaxLength 50
Hardware version of EV inverter. + *ISO 15118-20*: DER_BPT_AC_CPDReqEnergyTransferModeType: EVInverterHwVersion
chargingNeeds.derChargingParameters.evIslandingDetectionMethodarray<string>minItems 1; enum: NoAntiIslandingSupport, RoCoF, UVP_OVP, UFP_OFP, VoltageVectorShift, ZeroCrossingDetection, OtherPassive, ImpedanceMeasurement, ImpedanceAtFrequency, SlipModeFrequencyShift, SandiaFrequencyShift, SandiaVoltageShift, FrequencyJump, RCLQFactor, OtherActive
Type of islanding detection method. Only mandatory when islanding detection is required at the site, as set in the ISO 15118 Service Details configuration. + *ISO 15118-20*: DER_BPT_AC_CPDReqEnergyTransferModeType: EVIslandingDetectionMethod
chargingNeeds.derChargingParameters.evIslandingTripTimenumberTime after which EV will trip if an island has been detected. + *ISO 15118-20*: DER_BPT_AC_CPDReqEnergyTransferModeType: EVIslandingTripTime
chargingNeeds.derChargingParameters.evMaximumLevel1DCInjectionnumberMaximum injected DC current allowed at level 1 charging. + *ISO 15118-20*: DER_BPT_AC_CPDReqEnergyTransferModeType: EVMaximumLevel1DCInjection
chargingNeeds.derChargingParameters.evDurationLevel1DCInjectionnumberMaximum allowed duration of DC injection at level 1 charging. + *ISO 15118-20*: DER_BPT_AC_CPDReqEnergyTransferModeType: EVDurationLevel1DCInjection
chargingNeeds.derChargingParameters.evMaximumLevel2DCInjectionnumberMaximum injected DC current allowed at level 2 charging. + *ISO 15118-20*: DER_BPT_AC_CPDReqEnergyTransferModeType: EVMaximumLevel2DCInjection
chargingNeeds.derChargingParameters.evDurationLevel2DCInjectionnumberMaximum allowed duration of DC injection at level 2 charging. + *ISO 15118-20*: DER_BPT_AC_CPDReqEnergyTransferModeType: EVDurationLevel2DCInjection
chargingNeeds.derChargingParameters.evReactiveSusceptancenumberMeasure of the susceptibility of the circuit to reactance, in Siemens (S). + *ISO 15118-20*: DER_BPT_AC_CPDReqEnergyTransferModeType: EVReactiveSusceptance
chargingNeeds.derChargingParameters.evSessionTotalDischargeEnergyAvailablenumberTotal energy value, in Wh, that EV is allowed to provide during the entire V2G session. The value is independent of the V2X Cycling area. Once this value reaches the value of 0, the EV may block any attempt to discharge in order to protect the battery health. *ISO 15118-20*: DER_BPT_AC_CPDReqEnergyTransferModeType: EVSessionTotalDischargeEnergyAvailable
chargingNeeds.evEnergyOfferobject*(2.1)* A schedule of the energy amount over time that EV is willing to discharge. A negative value indicates the willingness to discharge under specific conditions, a positive value indicates that the EV currently is not able to offer energy to discharge.
chargingNeeds.evEnergyOffer.evAbsolutePriceScheduleobject*(2.1)* Price schedule of EV energy offer.
chargingNeeds.evEnergyOffer.evAbsolutePriceSchedule.timeAnchorstringPflichtformat date-time
Starting point in time of the EVEnergyOffer.
chargingNeeds.evEnergyOffer.evAbsolutePriceSchedule.currencystringPflichtmaxLength 3
Currency code according to ISO 4217.
chargingNeeds.evEnergyOffer.evAbsolutePriceSchedule.evAbsolutePriceScheduleEntriesarray<object>PflichtminItems 1; maxItems 1024
chargingNeeds.evEnergyOffer.evAbsolutePriceSchedule.evAbsolutePriceScheduleEntries[].durationintegerPflichtThe amount of seconds of this entry.
chargingNeeds.evEnergyOffer.evAbsolutePriceSchedule.evAbsolutePriceScheduleEntries[].evPriceRulearray<object>PflichtminItems 1; maxItems 8
chargingNeeds.evEnergyOffer.evAbsolutePriceSchedule.evAbsolutePriceScheduleEntries[].evPriceRule[].energyFeenumberPflichtCost per kWh.
chargingNeeds.evEnergyOffer.evAbsolutePriceSchedule.evAbsolutePriceScheduleEntries[].evPriceRule[].powerRangeStartnumberPflichtThe EnergyFee applies between this value and the value of the PowerRangeStart of the subsequent EVPriceRule. If the power is below this value, the EnergyFee of the previous EVPriceRule applies. Negative values are used for discharging.
chargingNeeds.evEnergyOffer.evAbsolutePriceSchedule.priceAlgorithmstringPflichtmaxLength 2000
ISO 15118-20 URN of price algorithm: Power, PeakPower, StackedEnergy.
chargingNeeds.evEnergyOffer.evPowerScheduleobjectPflicht*(2.1)* Schedule of EV energy offer.
chargingNeeds.evEnergyOffer.evPowerSchedule.evPowerScheduleEntriesarray<object>PflichtminItems 1; maxItems 1024
chargingNeeds.evEnergyOffer.evPowerSchedule.evPowerScheduleEntries[].durationintegerPflichtThe duration of this entry.
chargingNeeds.evEnergyOffer.evPowerSchedule.evPowerScheduleEntries[].powernumberPflichtDefines maximum amount of power for the duration of this EVPowerScheduleEntry to be discharged from the EV battery through EVSE power outlet. Negative values are used for discharging.
chargingNeeds.evEnergyOffer.evPowerSchedule.timeAnchorstringPflichtformat date-time
The time that defines the starting point for the EVEnergyOffer.
chargingNeeds.requestedEnergyTransferstringPflichtenum: AC_single_phase, AC_two_phase, AC_three_phase, DC, AC_BPT, AC_BPT_DER, AC_DER, DC_BPT, DC_ACDP, DC_ACDP_BPT, WPT
Mode of energy transfer requested by the EV.
chargingNeeds.dcChargingParametersobjectEV DC charging parameters for ISO 15118-2
chargingNeeds.dcChargingParameters.evMaxCurrentnumberPflichtMaximum current (in A) supported by the electric vehicle. Includes cable capacity. Relates to: + *ISO 15118-2*: DC_EVChargeParameterType:EVMaximumCurrentLimit
chargingNeeds.dcChargingParameters.evMaxVoltagenumberPflichtMaximum voltage supported by the electric vehicle. Relates to: + *ISO 15118-2*: DC_EVChargeParameterType: EVMaximumVoltageLimit
chargingNeeds.dcChargingParameters.evMaxPowernumberMaximum power (in W) supported by the electric vehicle. Required for DC charging. Relates to: + *ISO 15118-2*: DC_EVChargeParameterType: EVMaximumPowerLimit
chargingNeeds.dcChargingParameters.evEnergyCapacitynumberCapacity of the electric vehicle battery (in Wh). Relates to: + *ISO 15118-2*: DC_EVChargeParameterType: EVEnergyCapacity
chargingNeeds.dcChargingParameters.energyAmountnumberAmount of energy requested (in Wh). This inludes energy required for preconditioning. Relates to: + *ISO 15118-2*: DC_EVChargeParameterType: EVEnergyRequest
chargingNeeds.dcChargingParameters.stateOfChargeintegerminimum 0.0; maximum 100.0
Energy available in the battery (in percent of the battery capacity) Relates to: + *ISO 15118-2*: DC_EVChargeParameterType: DC_EVStatus: EVRESSSOC
chargingNeeds.dcChargingParameters.fullSoCintegerminimum 0.0; maximum 100.0
Percentage of SoC at which the EV considers the battery fully charged. (possible values: 0 - 100) Relates to: + *ISO 15118-2*: DC_EVChargeParameterType: FullSOC
chargingNeeds.dcChargingParameters.bulkSoCintegerminimum 0.0; maximum 100.0
Percentage of SoC at which the EV considers a fast charging process to end. (possible values: 0 - 100) Relates to: + *ISO 15118-2*: DC_EVChargeParameterType: BulkSOC
chargingNeeds.v2xChargingParametersobjectCharging parameters for ISO 15118-20, also supporting V2X charging/discharging.+ All values are greater or equal to zero, with the exception of EVMinEnergyRequest, EVMaxEnergyRequest, EVTargetEnergyRequest, EVMinV2XEnergyRequest and EVMaxV2XEnergyRequest.
chargingNeeds.v2xChargingParameters.minChargePowernumberMinimum charge power in W, defined by max(EV, EVSE). This field represents the sum of all phases, unless values are provided for L2 and L3, in which case this field represents phase L1. Relates to: *ISO 15118-20*: BPT_AC/DC_CPDReqEnergyTransferModeType: EVMinimumChargePower
chargingNeeds.v2xChargingParameters.minChargePower_L2numberMinimum charge power on phase L2 in W, defined by max(EV, EVSE). Relates to: *ISO 15118-20*: BPT_AC/DC_CPDReqEnergyTransferModeType: EVMinimumChargePower_L2
chargingNeeds.v2xChargingParameters.minChargePower_L3numberMinimum charge power on phase L3 in W, defined by max(EV, EVSE). Relates to: *ISO 15118-20*: BPT_AC/DC_CPDReqEnergyTransferModeType: EVMinimumChargePower_L3
chargingNeeds.v2xChargingParameters.maxChargePowernumberMaximum charge (absorbed) power in W, defined by min(EV, EVSE) at unity power factor. + This field represents the sum of all phases, unless values are provided for L2 and L3, in which case this field represents phase L1. It corresponds to the ChaWMax attribute in the IEC 61850. It is usually equivalent to the rated apparent power of the EV when discharging (ChaVAMax) in IEC 61850. + Relates to: *ISO 15118-20*: BPT_AC/DC_CPDReqEnergyTransferModeType: EVMaximumChargePower
chargingNeeds.v2xChargingParameters.maxChargePower_L2numberMaximum charge power on phase L2 in W, defined by min(EV, EVSE) Relates to: *ISO 15118-20*: BPT_AC/DC_CPDReqEnergyTransferModeType: EVMaximumChargePower_L2
chargingNeeds.v2xChargingParameters.maxChargePower_L3numberMaximum charge power on phase L3 in W, defined by min(EV, EVSE) Relates to: *ISO 15118-20*: BPT_AC/DC_CPDReqEnergyTransferModeType: EVMaximumChargePower_L3
chargingNeeds.v2xChargingParameters.minDischargePowernumberMinimum discharge (injected) power in W, defined by max(EV, EVSE) at unity power factor. Value &gt;= 0. + This field represents the sum of all phases, unless values are provided for L2 and L3, in which case this field represents phase L1. + It corresponds to the WMax attribute in the IEC 61850. It is usually equivalent to the rated apparent power of the EV when discharging (VAMax attribute in the IEC 61850). Relates to: *ISO 15118-20*: BPT_AC/DC_CPDReqEnergyTransferModeType: EVMinimumDischargePower
chargingNeeds.v2xChargingParameters.minDischargePower_L2numberMinimum discharge power on phase L2 in W, defined by max(EV, EVSE). Value &gt;= 0. Relates to: *ISO 15118-20*: BPT_AC/DC_CPDReqEnergyTransferModeType: EVMinimumDischargePower_L2
chargingNeeds.v2xChargingParameters.minDischargePower_L3numberMinimum discharge power on phase L3 in W, defined by max(EV, EVSE). Value &gt;= 0. Relates to: *ISO 15118-20*: BPT_AC/DC_CPDReqEnergyTransferModeType: EVMinimumDischargePower_L3
chargingNeeds.v2xChargingParameters.maxDischargePowernumberMaximum discharge (injected) power in W, defined by min(EV, EVSE) at unity power factor. Value &gt;= 0. This field represents the sum of all phases, unless values are provided for L2 and L3, in which case this field represents phase L1. Relates to: *ISO 15118-20*: BPT_AC/DC_CPDReqEnergyTransferModeType: EVMaximumDischargePower
chargingNeeds.v2xChargingParameters.maxDischargePower_L2numberMaximum discharge power on phase L2 in W, defined by min(EV, EVSE). Value &gt;= 0. Relates to: *ISO 15118-20*: BPT_AC/DC_CPDReqEnergyTransferModeType: EVMaximumDischargePowe_L2
chargingNeeds.v2xChargingParameters.maxDischargePower_L3numberMaximum discharge power on phase L3 in W, defined by min(EV, EVSE). Value &gt;= 0. Relates to: *ISO 15118-20*: BPT_AC/DC_CPDReqEnergyTransferModeType: EVMaximumDischargePower_L3
chargingNeeds.v2xChargingParameters.minChargeCurrentnumberMinimum charge current in A, defined by max(EV, EVSE) Relates to: *ISO 15118-20*: BPT_DC_CPDReqEnergyTransferModeType: EVMinimumChargeCurrent
chargingNeeds.v2xChargingParameters.maxChargeCurrentnumberMaximum charge current in A, defined by min(EV, EVSE) Relates to: *ISO 15118-20*: BPT_DC_CPDReqEnergyTransferModeType: EVMaximumChargeCurrent
chargingNeeds.v2xChargingParameters.minDischargeCurrentnumberMinimum discharge current in A, defined by max(EV, EVSE). Value &gt;= 0. Relates to: *ISO 15118-20*: BPT_DC_CPDReqEnergyTransferModeType: EVMinimumDischargeCurrent
chargingNeeds.v2xChargingParameters.maxDischargeCurrentnumberMaximum discharge current in A, defined by min(EV, EVSE). Value &gt;= 0. Relates to: *ISO 15118-20*: BPT_DC_CPDReqEnergyTransferModeType: EVMaximumDischargeCurrent
chargingNeeds.v2xChargingParameters.minVoltagenumberMinimum voltage in V, defined by max(EV, EVSE) Relates to: *ISO 15118-20*: BPT_DC_CPDReqEnergyTransferModeType: EVMinimumVoltage
chargingNeeds.v2xChargingParameters.maxVoltagenumberMaximum voltage in V, defined by min(EV, EVSE) Relates to: *ISO 15118-20*: BPT_DC_CPDReqEnergyTransferModeType: EVMaximumVoltage
chargingNeeds.v2xChargingParameters.evTargetEnergyRequestnumberEnergy to requested state of charge in Wh Relates to: *ISO 15118-20*: Dynamic/Scheduled_SEReqControlModeType: EVTargetEnergyRequest
chargingNeeds.v2xChargingParameters.evMinEnergyRequestnumberEnergy to minimum allowed state of charge in Wh Relates to: *ISO 15118-20*: Dynamic/Scheduled_SEReqControlModeType: EVMinimumEnergyRequest
chargingNeeds.v2xChargingParameters.evMaxEnergyRequestnumberEnergy to maximum state of charge in Wh Relates to: *ISO 15118-20*: Dynamic/Scheduled_SEReqControlModeType: EVMaximumEnergyRequest
chargingNeeds.v2xChargingParameters.evMinV2XEnergyRequestnumberEnergy (in Wh) to minimum state of charge for cycling (V2X) activity. Positive value means that current state of charge is below V2X range. Relates to: *ISO 15118-20*: Dynamic_SEReqControlModeType: EVMinimumV2XEnergyRequest
chargingNeeds.v2xChargingParameters.evMaxV2XEnergyRequestnumberEnergy (in Wh) to maximum state of charge for cycling (V2X) activity. Negative value indicates that current state of charge is above V2X range. Relates to: *ISO 15118-20*: Dynamic_SEReqControlModeType: EVMaximumV2XEnergyRequest
chargingNeeds.v2xChargingParameters.targetSoCintegerminimum 0.0; maximum 100.0
Target state of charge at departure as percentage. Relates to: *ISO 15118-20*: BPT_DC_CPDReqEnergyTransferModeType: TargetSOC
chargingNeeds.availableEnergyTransferarray<string>minItems 1; enum: AC_single_phase, AC_two_phase, AC_three_phase, DC, AC_BPT, AC_BPT_DER, AC_DER, DC_BPT, DC_ACDP, DC_ACDP_BPT, WPT
*(2.1)* Modes of energy transfer that are marked as available by EV.
chargingNeeds.controlModestringenum: ScheduledControl, DynamicControl
*(2.1)* Indicates whether EV wants to operate in Dynamic or Scheduled mode. When absent, Scheduled mode is assumed for backwards compatibility. + *ISO 15118-20:* + ServiceSelectionReq(SelectedEnergyTransferService)
chargingNeeds.mobilityNeedsModestringenum: EVCC, EVCC_SECC
*(2.1)* Value of EVCC indicates that EV determines min/target SOC and departure time. + A value of EVCC_SECC indicates that charging station or CSMS may also update min/target SOC and departure time. + *ISO 15118-20:* + ServiceSelectionReq(SelectedEnergyTransferService)
chargingNeeds.departureTimestringformat date-time
Estimated departure time of the EV. + *ISO 15118-2:* AC/DC_EVChargeParameterType: DepartureTime + *ISO 15118-20:* Dynamic/Scheduled_SEReqControlModeType: DepartureTIme
timestampstringformat date-time
*(2.1)* Time when EV charging needs were received. + Field can be added when charging station was offline when charging needs were received.
JSON-Schema (Request)
{
  "$schema": "http://json-schema.org/draft-06/schema#",
  "$id": "urn:OCPP:Cp:2:2025:1:NotifyEVChargingNeedsRequest",
  "comment": "OCPP 2.1 Edition 1 (c) OCA, Creative Commons Attribution-NoDerivatives 4.0 International Public License",
  "definitions": {
    "ControlModeEnumType": {
      "description": "*(2.1)* Indicates whether EV wants to operate in Dynamic or Scheduled mode. When absent, Scheduled mode is assumed for backwards compatibility. +\r\n*ISO 15118-20:* +\r\nServiceSelectionReq(SelectedEnergyTransferService)\r\n",
      "javaType": "ControlModeEnum",
      "type": "string",
      "additionalProperties": false,
      "enum": [
        "ScheduledControl",
        "DynamicControl"
      ]
    },
    "DERControlEnumType": {
      "javaType": "DERControlEnum",
      "type": "string",
      "additionalProperties": false,
      "enum": [
        "EnterService",
        "FreqDroop",
        "FreqWatt",
        "FixedPFAbsorb",
        "FixedPFInject",
        "FixedVar",
        "Gradients",
        "HFMustTrip",
        "HFMayTrip",
        "HVMustTrip",
        "HVMomCess",
        "HVMayTrip",
        "LimitMaxDischarge",
        "LFMustTrip",
        "LVMustTrip",
        "LVMomCess",
        "LVMayTrip",
        "PowerMonitoringMustTrip",
        "VoltVar",
        "VoltWatt",
        "WattPF",
        "WattVar"
      ]
    },
    "EnergyTransferModeEnumType": {
      "description": "Mode of energy transfer requested by the EV.\r\n",
      "javaType": "EnergyTransferModeEnum",
      "type": "string",
      "additionalProperties": false,
      "enum": [
        "AC_single_phase",
        "AC_two_phase",
        "AC_three_phase",
        "DC",
        "AC_BPT",
        "AC_BPT_DER",
        "AC_DER",
        "DC_BPT",
        "DC_ACDP",
        "DC_ACDP_BPT",
        "WPT"
      ]
    },
    "IslandingDetectionEnumType": {
      "javaType": "IslandingDetectionEnum",
      "type": "string",
      "additionalProperties": false,
      "enum": [
        "NoAntiIslandingSupport",
        "RoCoF",
        "UVP_OVP",
        "UFP_OFP",
        "VoltageVectorShift",
        "ZeroCrossingDetection",
        "OtherPassive",
        "ImpedanceMeasurement",
        "ImpedanceAtFrequency",
        "SlipModeFrequencyShift",
        "SandiaFrequencyShift",
        "SandiaVoltageShift",
        "FrequencyJump",
        "RCLQFactor",
        "OtherActive"
      ]
    },
    "MobilityNeedsModeEnumType": {
      "description": "*(2.1)* Value of EVCC indicates that EV determines min/target SOC and departure time. +\r\nA value of EVCC_SECC indicates that charging station or CSMS may also update min/target SOC and departure time. +\r\n*ISO 15118-20:* +\r\nServiceSelectionReq(SelectedEnergyTransferService)\r\n",
      "javaType": "MobilityNeedsModeEnum",
      "type": "string",
      "additionalProperties": false,
      "enum": [
        "EVCC",
        "EVCC_SECC"
      ]
    },
    "ACChargingParametersType": {
      "description": "EV AC charging parameters for ISO 15118-2\r\n\r\n",
      "javaType": "ACChargingParameters",
      "type": "object",
      "additionalProperties": false,
      "properties": {
        "energyAmount": {
          "description": "Amount of energy requested (in Wh). This includes energy required for preconditioning.\r\nRelates to: +\r\n*ISO 15118-2*: AC_EVChargeParameterType: EAmount +\r\n*ISO 15118-20*: Dynamic/Scheduled_SEReqControlModeType: EVTargetEnergyRequest\r\n\r\n",
          "type": "number"
        },
        "evMinCurrent": {
          "description": "Minimum current (amps) supported by the electric vehicle (per phase).\r\nRelates to: +\r\n*ISO 15118-2*: AC_EVChargeParameterType: EVMinCurrent\r\n\r\n",
          "type": "number"
        },
        "evMaxCurrent": {
          "description": "Maximum current (amps) supported by the electric vehicle (per phase). Includes cable capacity.\r\nRelates to: +\r\n*ISO 15118-2*: AC_EVChargeParameterType: EVMaxCurrent\r\n\r\n",
          "type": "number"
        },
        "evMaxVoltage": {
          "description": "Maximum voltage supported by the electric vehicle.\r\nRelates to: +\r\n*ISO 15118-2*: AC_EVChargeParameterType: EVMaxVoltage\r\n\r\n",
          "type": "number"
        },
        "customData": {
          "$ref": "#/definitions/CustomDataType"
        }
      },
      "required": [
        "energyAmount",
        "evMinCurrent",
        "evMaxCurrent",
        "evMaxVoltage"
      ]
    },
    "ChargingNeedsType": {
      "javaType": "ChargingNeeds",
      "type": "object",
      "additionalProperties": false,
      "properties": {
        "acChargingParameters": {
          "$ref": "#/definitions/ACChargingParametersType"
        },
        "derChargingParameters": {
          "$ref": "#/definitions/DERChargingParametersType"
        },
        "evEnergyOffer": {
          "$ref": "#/definitions/EVEnergyOfferType"
        },
        "requestedEnergyTransfer": {
          "$ref": "#/definitions/EnergyTransferModeEnumType"
        },
        "dcChargingParameters": {
          "$ref": "#/definitions/DCChargingParametersType"
        },
        "v2xChargingParameters": {
          "$ref": "#/definitions/V2XChargingParametersType"
        },
        "availableEnergyTransfer": {
          "description": "*(2.1)* Modes of energy transfer that are marked as available by EV.\r\n",
          "type": "array",
          "additionalItems": false,
          "items": {
            "$ref": "#/definitions/EnergyTransferModeEnumType"
          },
          "minItems": 1
        },
        "controlMode": {
          "$ref": "#/definitions/ControlModeEnumType"
        },
        "mobilityNeedsMode": {
          "$ref": "#/definitions/MobilityNeedsModeEnumType"
        },
        "departureTime": {
          "description": "Estimated departure time of the EV. +\r\n*ISO 15118-2:* AC/DC_EVChargeParameterType: DepartureTime +\r\n*ISO 15118-20:* Dynamic/Scheduled_SEReqControlModeType: DepartureTIme\r\n",
          "type": "string",
          "format": "date-time"
        },
        "customData": {
          "$ref": "#/definitions/CustomDataType"
        }
      },
      "required": [
        "requestedEnergyTransfer"
      ]
    },
    "DCChargingParametersType": {
      "description": "EV DC charging parameters for ISO 15118-2\r\n",
      "javaType": "DCChargingParameters",
      "type": "object",
      "additionalProperties": false,
      "properties": {
        "evMaxCurrent": {
          "description": "Maximum current (in A) supported by the electric vehicle. Includes cable capacity.\r\nRelates to: +\r\n*ISO 15118-2*: DC_EVChargeParameterType:EVMaximumCurrentLimit\r\n",
          "type": "number"
        },
        "evMaxVoltage": {
          "description": "Maximum voltage supported by the electric vehicle.\r\nRelates to: +\r\n*ISO 15118-2*: DC_EVChargeParameterType: EVMaximumVoltageLimit\r\n\r\n",
          "type": "number"
        },
        "evMaxPower": {
          "description": "Maximum power (in W) supported by the electric vehicle. Required for DC charging.\r\nRelates to: +\r\n*ISO 15118-2*: DC_EVChargeParameterType: EVMaximumPowerLimit\r\n\r\n",
          "type": "number"
        },
        "evEnergyCapacity": {
          "description": "Capacity of the electric vehicle battery (in Wh).\r\nRelates to: +\r\n*ISO 15118-2*: DC_EVChargeParameterType: EVEnergyCapacity\r\n\r\n",
          "type": "number"
        },
        "energyAmount": {
          "description": "Amount of energy requested (in Wh). This inludes energy required for preconditioning.\r\nRelates to: +\r\n*ISO 15118-2*: DC_EVChargeParameterType: EVEnergyRequest\r\n\r\n\r\n",
          "type": "number"
        },
        "stateOfCharge": {
          "description": "Energy available in the battery (in percent of the battery capacity)\r\nRelates to: +\r\n*ISO 15118-2*: DC_EVChargeParameterType: DC_EVStatus: EVRESSSOC\r\n\r\n",
          "type": "integer",
          "minimum": 0.0,
          "maximum": 100.0
        },
        "fullSoC": {
          "description": "Percentage of SoC at which the EV considers the battery fully charged. (possible values: 0 - 100)\r\nRelates to: +\r\n*ISO 15118-2*: DC_EVChargeParameterType: FullSOC\r\n\r\n",
          "type": "integer",
          "minimum": 0.0,
          "maximum": 100.0
        },
        "bulkSoC": {
          "description": "Percentage of SoC at which the EV considers a fast charging process to end. (possible values: 0 - 100)\r\nRelates to: +\r\n*ISO 15118-2*: DC_EVChargeParameterType: BulkSOC\r\n\r\n",
          "type": "integer",
          "minimum": 0.0,
          "maximum": 100.0
        },
        "customData": {
          "$ref": "#/definitions/CustomDataType"
        }
      },
      "required": [
        "evMaxCurrent",
        "evMaxVoltage"
      ]
    },
    "DERChargingParametersType": {
      "description": "*(2.1)* DERChargingParametersType is used in ChargingNeedsType during an ISO 15118-20 session for AC_BPT_DER to report the inverter settings related to DER control that were agreed between EVSE and EV.\r\n\r\nFields starting with \"ev\" contain values from the EV.\r\nOther fields contain a value that is supported by both EV and EVSE.\r\n\r\nDERChargingParametersType type is only relevant in case of an ISO 15118-20 AC_BPT_DER/AC_DER charging session.\r\n\r\nNOTE: All these fields have values greater or equal to zero (i.e. are non-negative)\r\n\r\n",
      "javaType": "DERChargingParameters",
      "type": "object",
      "additionalProperties": false,
      "properties": {
        "evSupportedDERControl": {
          "description": "DER control functions supported by EV. +\r\n    *ISO 15118-20*: DER_BPT_AC_CPDReqEnergyTransferModeType:DERControlFunctions (bitmap)\r\n",
          "type": "array",
          "additionalItems": false,
          "items": {
            "$ref": "#/definitions/DERControlEnumType"
          },
          "minItems": 1
        },
        "evOverExcitedMaxDischargePower": {
          "description": "Rated maximum injected active power by EV, at specified over-excited power factor (overExcitedPowerFactor). +\r\nIt can also be defined as the rated maximum discharge power at the rated minimum injected reactive power value. This means that if the EV is providing reactive power support, and it is requested to discharge at max power (e.g. to satisfy an EMS request), the EV may override the request and discharge up to overExcitedMaximumDischargePower to meet the minimum reactive power requirements. +\r\nCorresponds to the WOvPF attribute in IEC 61850. +\r\n    *ISO 15118-20*: DER_BPT_AC_CPDReqEnergyTransferModeType: EVOverExcitedMaximumDischargePower\r\n",
          "type": "number"
        },
        "evOverExcitedPowerFactor": {
          "description": "EV power factor when injecting (over excited) the minimum reactive power. +\r\nCorresponds to the OvPF attribute in IEC 61850. +\r\n    *ISO 15118-20*: DER_BPT_AC_CPDReqEnergyTransferModeType: EVOverExcitedPowerFactor\r\n",
          "type": "number"
        },
        "evUnderExcitedMaxDischargePower": {
          "description": "Rated maximum injected active power by EV supported at specified under-excited power factor (EVUnderExcitedPowerFactor). +\r\nIt can also be defined as the rated maximum dischargePower at the rated minimum absorbed reactive power value.\r\nThis means that if the EV is providing reactive power support, and it is requested to discharge at max power (e.g. to satisfy an EMS request), the EV may override the request and discharge up to underExcitedMaximumDischargePower to meet the minimum reactive power requirements. +\r\nThis corresponds to the WUnPF attribute in the IEC 61850. +\r\n    *ISO 15118-20*: DER_BPT_AC_CPDReqEnergyTransferModeType: EVUnderExcitedMaximumDischargePower\r\n",
          "type": "number"
        },
        "evUnderExcitedPowerFactor": {
          "description": "EV power factor when injecting (under excited) the minimum reactive power. +\r\nCorresponds to the OvPF attribute in IEC 61850. +\r\n    *ISO 15118-20*: DER_BPT_AC_CPDReqEnergyTransferModeType: EVUnderExcitedPowerFactor\r\n",
          "type": "number"
        },
        "maxApparentPower": {
          "description": "Rated maximum total apparent power, defined by min(EV, EVSE) in va.\r\nCorresponds to the VAMaxRtg in IEC 61850. +\r\n    *ISO 15118-20*: DER_BPT_AC_CPDReqEnergyTransferModeType: EVMaximumApparentPower\r\n",
          "type": "number"
        },
        "maxChargeApparentPower": {
          "description": "Rated maximum absorbed apparent power, defined by min(EV, EVSE) in va. +\r\n    This field represents the sum of all phases, unless values are provided for L2 and L3,\r\n    in which case this field represents phase L1. +\r\n    Corresponds to the ChaVAMaxRtg in IEC 61850. +\r\n    *ISO 15118-20*: DER_BPT_AC_CPDReqEnergyTransferModeType: EVMaximumChargeApparentPower\r\n",
          "type": "number"
        },
        "maxChargeApparentPower_L2": {
          "description": "Rated maximum absorbed apparent power on phase L2, defined by min(EV, EVSE) in va.\r\nCorresponds to the ChaVAMaxRtg in IEC 61850. +\r\n    *ISO 15118-20*: DER_BPT_AC_CPDReqEnergyTransferModeType: EVMaximumChargeApparentPower_L2\r\n",
          "type": "number"
        },
        "maxChargeApparentPower_L3": {
          "description": "Rated maximum absorbed apparent power on phase L3, defined by min(EV, EVSE) in va.\r\nCorresponds to the ChaVAMaxRtg in IEC 61850. +\r\n    *ISO 15118-20*: DER_BPT_AC_CPDReqEnergyTransferModeType: EVMaximumChargeApparentPower_L3\r\n",
          "type": "number"
        },
        "maxDischargeApparentPower": {
          "description": "Rated maximum injected apparent power, defined by min(EV, EVSE) in va. +\r\n    This field represents the sum of all phases, unless values are provided for L2 and L3,\r\n    in which case this field represents phase L1. +\r\n    Corresponds to the DisVAMaxRtg in IEC 61850. +\r\n    *ISO 15118-20*: DER_BPT_AC_CPDReqEnergyTransferModeType: EVMaximumDischargeApparentPower\r\n",
          "type": "number"
        },
        "maxDischargeApparentPower_L2": {
          "description": "Rated maximum injected apparent power on phase L2, defined by min(EV, EVSE) in va. +\r\n    Corresponds to the DisVAMaxRtg in IEC 61850. +\r\n    *ISO 15118-20*: DER_BPT_AC_CPDReqEnergyTransferModeType: EVMaximumDischargeApparentPower_L2\r\n",
          "type": "number"
        },
        "maxDischargeApparentPower_L3": {
          "description": "Rated maximum injected apparent power on phase L3, defined by min(EV, EVSE) in va. +\r\n    Corresponds to the DisVAMaxRtg in IEC 61850. +\r\n    *ISO 15118-20*: DER_BPT_AC_CPDReqEnergyTransferModeType: EVMaximumDischargeApparentPower_L3\r\n",
          "type": "number"
        },
        "maxChargeReactivePower": {
          "description": "Rated maximum absorbed reactive power, defined by min(EV, EVSE), in vars. +\r\n    This field represents the sum of all phases, unless values are provided for L2 and L3,\r\n    in which case this field represents phase L1. +\r\nCorresponds to the AvarMax attribute in the IEC 61850. +\r\n    *ISO 15118-20*: DER_BPT_AC_CPDReqEnergyTransferModeType: EVMaximumChargeReactivePower\r\n",
          "type": "number"
        },
        "maxChargeReactivePower_L2": {
          "description": "Rated maximum absorbed reactive power, defined by min(EV, EVSE), in vars on phase L2. +\r\nCorresponds to the AvarMax attribute in the IEC 61850. +\r\n    *ISO 15118-20*: DER_BPT_AC_CPDReqEnergyTransferModeType: EVMaximumChargeReactivePower_L2\r\n",
          "type": "number"
        },
        "maxChargeReactivePower_L3": {
          "description": "Rated maximum absorbed reactive power, defined by min(EV, EVSE), in vars on phase L3. +\r\nCorresponds to the AvarMax attribute in the IEC 61850. +\r\n    *ISO 15118-20*: DER_BPT_AC_CPDReqEnergyTransferModeType: EVMaximumChargeReactivePower_L3\r\n",
          "type": "number"
        },
        "minChargeReactivePower": {
          "description": "Rated minimum absorbed reactive power, defined by max(EV, EVSE), in vars. +\r\n    This field represents the sum of all phases, unless values are provided for L2 and L3,\r\n    in which case this field represents phase L1. +\r\n    *ISO 15118-20*: DER_BPT_AC_CPDReqEnergyTransferModeType: EVMinimumChargeReactivePower\r\n",
          "type": "number"
        },
        "minChargeReactivePower_L2": {
          "description": "Rated minimum absorbed reactive power, defined by max(EV, EVSE), in vars on phase L2. +\r\n    *ISO 15118-20*: DER_BPT_AC_CPDReqEnergyTransferModeType: EVMinimumChargeReactivePower_L2\r\n",
          "type": "number"
        },
        "minChargeReactivePower_L3": {
          "description": "Rated minimum absorbed reactive power, defined by max(EV, EVSE), in vars on phase L3. +\r\n    *ISO 15118-20*: DER_BPT_AC_CPDReqEnergyTransferModeType: EVMinimumChargeReactivePower_L3\r\n",
          "type": "number"
        },
        "maxDischargeReactivePower": {
          "description": "Rated maximum injected reactive power, defined by min(EV, EVSE), in vars. +\r\n    This field represents the sum of all phases, unless values are provided for L2 and L3,\r\n    in which case this field represents phase L1. +\r\nCorresponds to the IvarMax attribute in the IEC 61850. +\r\n    *ISO 15118-20*: DER_BPT_AC_CPDReqEnergyTransferModeType: EVMaximumDischargeReactivePower\r\n",
          "type": "number"
        },
        "maxDischargeReactivePower_L2": {
          "description": "Rated maximum injected reactive power, defined by min(EV, EVSE), in vars on phase L2. +\r\nCorresponds to the IvarMax attribute in the IEC 61850. +\r\n    *ISO 15118-20*: DER_BPT_AC_CPDReqEnergyTransferModeType: EVMaximumDischargeReactivePower_L2\r\n",
          "type": "number"
        },
        "maxDischargeReactivePower_L3": {
          "description": "Rated maximum injected reactive power, defined by min(EV, EVSE), in vars on phase L3. +\r\nCorresponds to the IvarMax attribute in the IEC 61850. +\r\n    *ISO 15118-20*: DER_BPT_AC_CPDReqEnergyTransferModeType: EVMaximumDischargeReactivePower_L3\r\n",
          "type": "number"
        },
        "minDischargeReactivePower": {
          "description": "Rated minimum injected reactive power, defined by max(EV, EVSE), in vars. +\r\n    This field represents the sum of all phases, unless values are provided for L2 and L3,\r\n    in which case this field represents phase L1. +\r\n        *ISO 15118-20*: DER_BPT_AC_CPDReqEnergyTransferModeType: EVMinimumDischargeReactivePower\r\n",
          "type": "number"
        },
        "minDischargeReactivePower_L2": {
          "description": "Rated minimum injected reactive power, defined by max(EV, EVSE), in var on phase L2. +\r\n        *ISO 15118-20*: DER_BPT_AC_CPDReqEnergyTransferModeType: EVMinimumDischargeReactivePower_L2\r\n",
          "type": "number"
        },
        "minDischargeReactivePower_L3": {
          "description": "Rated minimum injected reactive power, defined by max(EV, EVSE), in var on phase L3. +\r\n        *ISO 15118-20*: DER_BPT_AC_CPDReqEnergyTransferModeType: EVMinimumDischargeReactivePower_L3\r\n",
          "type": "number"
        },
        "nominalVoltage": {
          "description": "Line voltage supported by EVSE and EV.\r\n        *ISO 15118-20*: DER_BPT_AC_CPDReqEnergyTransferModeType: EVNominalVoltage\r\n",
          "type": "number"
        },
        "nominalVoltageOffset": {
          "description": "The nominal AC voltage (rms) offset between the Charging Station's electrical connection point and the utility’s point of common coupling. +\r\n        *ISO 15118-20*: DER_BPT_AC_CPDReqEnergyTransferModeType: EVNominalVoltageOffset\r\n",
          "type": "number"
        },
        "maxNominalVoltage": {
          "description": "Maximum AC rms voltage, as defined by min(EV, EVSE)  to operate with. +\r\n       *ISO 15118-20*: DER_BPT_AC_CPDReqEnergyTransferModeType: EVMaximumNominalVoltage\r\n",
          "type": "number"
        },
        "minNominalVoltage": {
          "description": "Minimum AC rms voltage, as defined by max(EV, EVSE)  to operate with. +\r\n       *ISO 15118-20*: DER_BPT_AC_CPDReqEnergyTransferModeType: EVMinimumNominalVoltage\r\n",
          "type": "number"
        },
        "evInverterManufacturer": {
          "description": "Manufacturer of the EV inverter. +\r\n       *ISO 15118-20*: DER_BPT_AC_CPDReqEnergyTransferModeType: EVInverterManufacturer\r\n",
          "type": "string",
          "maxLength": 50
        },
        "evInverterModel": {
          "description": "Model name of the EV inverter. +\r\n       *ISO 15118-20*: DER_BPT_AC_CPDReqEnergyTransferModeType: EVInverterModel\r\n",
          "type": "string",
          "maxLength": 50
        },
        "evInverterSerialNumber": {
          "description": "Serial number of the EV inverter. +\r\n       *ISO 15118-20*: DER_BPT_AC_CPDReqEnergyTransferModeType: EVInverterSerialNumber\r\n",
          "type": "string",
          "maxLength": 50
        },
        "evInverterSwVersion": {
          "description": "Software version of EV inverter. +\r\n       *ISO 15118-20*: DER_BPT_AC_CPDReqEnergyTransferModeType: EVInverterSwVersion\r\n",
          "type": "string",
          "maxLength": 50
        },
        "evInverterHwVersion": {
          "description": "Hardware version of EV inverter. +\r\n       *ISO 15118-20*: DER_BPT_AC_CPDReqEnergyTransferModeType: EVInverterHwVersion\r\n",
          "type": "string",
          "maxLength": 50
        },
        "evIslandingDetectionMethod": {
          "description": "Type of islanding detection method. Only mandatory when islanding detection is required at the site, as set in the ISO 15118 Service Details configuration. +\r\n       *ISO 15118-20*: DER_BPT_AC_CPDReqEnergyTransferModeType: EVIslandingDetectionMethod\r\n",
          "type": "array",
          "additionalItems": false,
          "items": {
            "$ref": "#/definitions/IslandingDetectionEnumType"
          },
          "minItems": 1
        },
        "evIslandingTripTime": {
          "description": "Time after which EV will trip if an island has been detected. +\r\n       *ISO 15118-20*: DER_BPT_AC_CPDReqEnergyTransferModeType: EVIslandingTripTime\r\n",
          "type": "number"
        },
        "evMaximumLevel1DCInjection": {
          "description": "Maximum injected DC current allowed at level 1 charging. +\r\n       *ISO 15118-20*: DER_BPT_AC_CPDReqEnergyTransferModeType: EVMaximumLevel1DCInjection\r\n",
          "type": "number"
        },
        "evDurationLevel1DCInjection": {
          "description": "Maximum allowed duration of DC injection at level 1 charging. +\r\n       *ISO 15118-20*: DER_BPT_AC_CPDReqEnergyTransferModeType: EVDurationLevel1DCInjection\r\n",
          "type": "number"
        },
        "evMaximumLevel2DCInjection": {
          "description": "Maximum injected DC current allowed at level 2 charging. +\r\n       *ISO 15118-20*: DER_BPT_AC_CPDReqEnergyTransferModeType: EVMaximumLevel2DCInjection\r\n",
          "type": "number"
        },
        "evDurationLevel2DCInjection": {
          "description": "Maximum allowed duration of DC injection at level 2 charging. +\r\n       *ISO 15118-20*: DER_BPT_AC_CPDReqEnergyTransferModeType: EVDurationLevel2DCInjection\r\n",
          "type": "number"
        },
        "evReactiveSusceptance": {
          "description": "\tMeasure of the susceptibility of the circuit to reactance, in Siemens (S). +\r\n       *ISO 15118-20*: DER_BPT_AC_CPDReqEnergyTransferModeType: EVReactiveSusceptance\r\n\r\n\r\n",
          "type": "number"
        },
        "evSessionTotalDischargeEnergyAvailable": {
          "description": "Total energy value, in Wh, that EV is allowed to provide during the entire V2G session. The value is independent of the V2X Cycling area. Once this value reaches the value of 0, the EV may block any attempt to discharge in order to protect the battery health.\r\n       *ISO 15118-20*: DER_BPT_AC_CPDReqEnergyTransferModeType: EVSessionTotalDischargeEnergyAvailable\r\n\r\n\r\n",
          "type": "number"
        },
        "customData": {
          "$ref": "#/definitions/CustomDataType"
        }
      }
    },
    "EVAbsolutePriceScheduleEntryType": {
      "description": "*(2.1)* An entry in price schedule over time for which EV is willing to discharge.\r\n",
      "javaType": "EVAbsolutePriceScheduleEntry",
      "type": "object",
      "additionalProperties": false,
      "properties": {
        "duration": {
          "description": "The amount of seconds of this entry.\r\n",
          "type": "integer"
        },
        "evPriceRule": {
          "type": "array",
          "additionalItems": false,
          "items": {
            "$ref": "#/definitions/EVPriceRuleType"
          },
          "minItems": 1,
          "maxItems": 8
        },
        "customData": {
          "$ref": "#/definitions/CustomDataType"
        }
      },
      "required": [
        "duration",
        "evPriceRule"
      ]
    },
    "EVAbsolutePriceScheduleType": {
      "description": "*(2.1)* Price schedule of EV energy offer.\r\n",
      "javaType": "EVAbsolutePriceSchedule",
      "type": "object",
      "additionalProperties": false,
      "properties": {
        "timeAnchor": {
          "description": "Starting point in time of the EVEnergyOffer.\r\n",
          "type": "string",
          "format": "date-time"
        },
        "currency": {
          "description": "Currency code according to ISO 4217.\r\n",
          "type": "string",
          "maxLength": 3
        },
        "evAbsolutePriceScheduleEntries": {
          "type": "array",
          "additionalItems": false,
          "items": {
            "$ref": "#/definitions/EVAbsolutePriceScheduleEntryType"
          },
          "minItems": 1,
          "maxItems": 1024
        },
        "priceAlgorithm": {
          "description": "ISO 15118-20 URN of price algorithm: Power, PeakPower, StackedEnergy.\r\n",
          "type": "string",
          "maxLength": 2000
        },
        "customData": {
          "$ref": "#/definitions/CustomDataType"
        }
      },
      "required": [
        "timeAnchor",
        "currency",
        "priceAlgorithm",
        "evAbsolutePriceScheduleEntries"
      ]
    },
    "EVEnergyOfferType": {
      "description": "*(2.1)* A schedule of the energy amount over time that EV is willing to discharge. A negative value indicates the willingness to discharge under specific conditions, a positive value indicates that the EV currently is not able to offer energy to discharge. \r\n",
      "javaType": "EVEnergyOffer",
      "type": "object",
      "additionalProperties": false,
      "properties": {
        "evAbsolutePriceSchedule": {
          "$ref": "#/definitions/EVAbsolutePriceScheduleType"
        },
        "evPowerSchedule": {
          "$ref": "#/definitions/EVPowerScheduleType"
        },
        "customData": {
          "$ref": "#/definitions/CustomDataType"
        }
      },
      "required": [
        "evPowerSchedule"
      ]
    },
    "EVPowerScheduleEntryType": {
      "description": "*(2.1)* An entry in schedule of the energy amount over time that EV is willing to discharge. A negative value indicates the willingness to discharge under specific conditions, a positive value indicates that the EV currently is not able to offer energy to discharge.\r\n",
      "javaType": "EVPowerScheduleEntry",
      "type": "object",
      "additionalProperties": false,
      "properties": {
        "duration": {
          "description": "The duration of this entry.\r\n",
          "type": "integer"
        },
        "power": {
          "description": "Defines maximum amount of power for the duration of this EVPowerScheduleEntry to be discharged from the EV battery through EVSE power outlet. Negative values are used for discharging.\r\n",
          "type": "number"
        },
        "customData": {
          "$ref": "#/definitions/CustomDataType"
        }
      },
      "required": [
        "duration",
        "power"
      ]
    },
    "EVPowerScheduleType": {
      "description": "*(2.1)* Schedule of EV energy offer.\r\n",
      "javaType": "EVPowerSchedule",
      "type": "object",
      "additionalProperties": false,
      "properties": {
        "evPowerScheduleEntries": {
          "type": "array",
          "additionalItems": false,
          "items": {
            "$ref": "#/definitions/EVPowerScheduleEntryType"
          },
          "minItems": 1,
          "maxItems": 1024
        },
        "timeAnchor": {
          "description": "The time that defines the starting point for the EVEnergyOffer.\r\n",
          "type": "string",
          "format": "date-time"
        },
        "customData": {
          "$ref": "#/definitions/CustomDataType"
        }
      },
      "required": [
        "timeAnchor",
        "evPowerScheduleEntries"
      ]
    },
    "EVPriceRuleType": {
      "description": "*(2.1)* An entry in price schedule over time for which EV is willing to discharge.\r\n",
      "javaType": "EVPriceRule",
      "type": "object",
      "additionalProperties": false,
      "properties": {
        "energyFee": {
          "description": "Cost per kWh.\r\n",
          "type": "number"
        },
        "powerRangeStart": {
          "description": "The EnergyFee applies between this value and the value of the PowerRangeStart of the subsequent EVPriceRule. If the power is below this value, the EnergyFee of the previous EVPriceRule applies. Negative values are used for discharging.\r\n",
          "type": "number"
        },
        "customData": {
          "$ref": "#/definitions/CustomDataType"
        }
      },
      "required": [
        "energyFee",
        "powerRangeStart"
      ]
    },
    "V2XChargingParametersType": {
      "description": "Charging parameters for ISO 15118-20, also supporting V2X charging/discharging.+\r\nAll values are greater or equal to zero, with the exception of EVMinEnergyRequest, EVMaxEnergyRequest, EVTargetEnergyRequest, EVMinV2XEnergyRequest and EVMaxV2XEnergyRequest.\r\n",
      "javaType": "V2XChargingParameters",
      "type": "object",
      "additionalProperties": false,
      "properties": {
        "minChargePower": {
          "description": "Minimum charge power in W, defined by max(EV, EVSE).\r\nThis field represents the sum of all phases, unless values are provided for L2 and L3, in which case this field represents phase L1.\r\nRelates to:\r\n*ISO 15118-20*: BPT_AC/DC_CPDReqEnergyTransferModeType: EVMinimumChargePower\r\n",
          "type": "number"
        },
        "minChargePower_L2": {
          "description": "Minimum charge power on phase L2 in W, defined by max(EV, EVSE).\r\nRelates to:\r\n*ISO 15118-20*: BPT_AC/DC_CPDReqEnergyTransferModeType: EVMinimumChargePower_L2\r\n",
          "type": "number"
        },
        "minChargePower_L3": {
          "description": "Minimum charge power on phase L3 in W, defined by max(EV, EVSE).\r\nRelates to:\r\n*ISO 15118-20*: BPT_AC/DC_CPDReqEnergyTransferModeType: EVMinimumChargePower_L3\r\n",
          "type": "number"
        },
        "maxChargePower": {
          "description": "Maximum charge (absorbed) power in W, defined by min(EV, EVSE) at unity power factor. +\r\nThis field represents the sum of all phases, unless values are provided for L2 and L3, in which case this field represents phase L1.\r\nIt corresponds to the ChaWMax attribute in the IEC 61850.\r\nIt is usually equivalent to the rated apparent power of the EV when discharging (ChaVAMax) in IEC 61850. +\r\n\r\nRelates to: \r\n*ISO 15118-20*: BPT_AC/DC_CPDReqEnergyTransferModeType: EVMaximumChargePower\r\n\r\n",
          "type": "number"
        },
        "maxChargePower_L2": {
          "description": "Maximum charge power on phase L2 in W, defined by min(EV, EVSE)\r\nRelates to: \r\n*ISO 15118-20*: BPT_AC/DC_CPDReqEnergyTransferModeType: EVMaximumChargePower_L2\r\n\r\n\r\n",
          "type": "number"
        },
        "maxChargePower_L3": {
          "description": "Maximum charge power on phase L3 in W, defined by min(EV, EVSE)\r\nRelates to: \r\n*ISO 15118-20*: BPT_AC/DC_CPDReqEnergyTransferModeType: EVMaximumChargePower_L3\r\n\r\n\r\n",
          "type": "number"
        },
        "minDischargePower": {
          "description": "Minimum discharge (injected) power in W, defined by max(EV, EVSE) at unity power factor. Value &gt;= 0. +\r\nThis field represents the sum of all phases, unless values are provided for L2 and L3, in which case this field represents phase L1. +\r\nIt corresponds to the WMax attribute in the IEC 61850.\r\nIt is usually equivalent to the rated apparent power of the EV when discharging (VAMax attribute in the IEC 61850).\r\n\r\nRelates to:\r\n*ISO 15118-20*: BPT_AC/DC_CPDReqEnergyTransferModeType: EVMinimumDischargePower\r\n\r\n",
          "type": "number"
        },
        "minDischargePower_L2": {
          "description": "Minimum discharge power on phase L2 in W, defined by max(EV, EVSE).  Value &gt;= 0.\r\nRelates to:\r\n*ISO 15118-20*: BPT_AC/DC_CPDReqEnergyTransferModeType: EVMinimumDischargePower_L2\r\n\r\n",
          "type": "number"
        },
        "minDischargePower_L3": {
          "description": "Minimum discharge power on phase L3 in W, defined by max(EV, EVSE).  Value &gt;= 0.\r\nRelates to:\r\n*ISO 15118-20*: BPT_AC/DC_CPDReqEnergyTransferModeType: EVMinimumDischargePower_L3\r\n\r\n",
          "type": "number"
        },
        "maxDischargePower": {
          "description": "Maximum discharge (injected) power in W, defined by min(EV, EVSE) at unity power factor.  Value &gt;= 0.\r\nThis field represents the sum of all phases, unless values are provided for L2 and L3, in which case this field represents phase L1.\r\nRelates to:\r\n*ISO 15118-20*: BPT_AC/DC_CPDReqEnergyTransferModeType: EVMaximumDischargePower\r\n\r\n\r\n",
          "type": "number"
        },
        "maxDischargePower_L2": {
          "description": "Maximum discharge power on phase L2 in W, defined by min(EV, EVSE).  Value &gt;= 0.\r\nRelates to:\r\n*ISO 15118-20*: BPT_AC/DC_CPDReqEnergyTransferModeType: EVMaximumDischargePowe_L2\r\n\r\n",
          "type": "number"
        },
        "maxDischargePower_L3": {
          "description": "Maximum discharge power on phase L3 in W, defined by min(EV, EVSE).  Value &gt;= 0.\r\nRelates to:\r\n*ISO 15118-20*: BPT_AC/DC_CPDReqEnergyTransferModeType: EVMaximumDischargePower_L3\r\n\r\n",
          "type": "number"
        },
        "minChargeCurrent": {
          "description": "Minimum charge current in A, defined by max(EV, EVSE)\r\nRelates to: \r\n*ISO 15118-20*: BPT_DC_CPDReqEnergyTransferModeType: EVMinimumChargeCurrent\r\n\r\n",
          "type": "number"
        },
        "maxChargeCurrent": {
          "description": "Maximum charge current in A, defined by min(EV, EVSE)\r\nRelates to: \r\n*ISO 15118-20*: BPT_DC_CPDReqEnergyTransferModeType: EVMaximumChargeCurrent\r\n\r\n\r\n",
          "type": "number"
        },
        "minDischargeCurrent": {
          "description": "Minimum discharge current in A, defined by max(EV, EVSE).  Value &gt;= 0.\r\nRelates to: \r\n*ISO 15118-20*: BPT_DC_CPDReqEnergyTransferModeType: EVMinimumDischargeCurrent\r\n\r\n\r\n",
          "type": "number"
        },
        "maxDischargeCurrent": {
          "description": "Maximum discharge current in A, defined by min(EV, EVSE).  Value &gt;= 0.\r\nRelates to: \r\n*ISO 15118-20*: BPT_DC_CPDReqEnergyTransferModeType: EVMaximumDischargeCurrent\r\n\r\n",
          "type": "number"
        },
        "minVoltage": {
          "description": "Minimum voltage in V, defined by max(EV, EVSE)\r\nRelates to:\r\n*ISO 15118-20*: BPT_DC_CPDReqEnergyTransferModeType: EVMinimumVoltage\r\n\r\n",
          "type": "number"
        },
        "maxVoltage": {
          "description": "Maximum voltage in V, defined by min(EV, EVSE)\r\nRelates to:\r\n*ISO 15118-20*: BPT_DC_CPDReqEnergyTransferModeType: EVMaximumVoltage\r\n\r\n",
          "type": "number"
        },
        "evTargetEnergyRequest": {
          "description": "Energy to requested state of charge in Wh\r\nRelates to:\r\n*ISO 15118-20*: Dynamic/Scheduled_SEReqControlModeType: EVTargetEnergyRequest\r\n\r\n",
          "type": "number"
        },
        "evMinEnergyRequest": {
          "description": "Energy to minimum allowed state of charge in Wh\r\nRelates to:\r\n*ISO 15118-20*: Dynamic/Scheduled_SEReqControlModeType: EVMinimumEnergyRequest\r\n\r\n",
          "type": "number"
        },
        "evMaxEnergyRequest": {
          "description": "Energy to maximum state of charge in Wh\r\nRelates to:\r\n*ISO 15118-20*: Dynamic/Scheduled_SEReqControlModeType: EVMaximumEnergyRequest\r\n\r\n",
          "type": "number"
        },
        "evMinV2XEnergyRequest": {
          "description": "Energy (in Wh) to minimum state of charge for cycling (V2X) activity. \r\nPositive value means that current state of charge is below V2X range.\r\nRelates to:\r\n*ISO 15118-20*: Dynamic_SEReqControlModeType: EVMinimumV2XEnergyRequest\r\n\r\n",
          "type": "number"
        },
        "evMaxV2XEnergyRequest": {
          "description": "Energy (in Wh) to maximum state of charge for cycling (V2X) activity.\r\nNegative value indicates that current state of charge is above V2X range.\r\nRelates to:\r\n*ISO 15118-20*: Dynamic_SEReqControlModeType: EVMaximumV2XEnergyRequest\r\n\r\n\r\n",
          "type": "number"
        },
        "targetSoC": {
          "description": "Target state of charge at departure as percentage.\r\nRelates to:\r\n*ISO 15118-20*: BPT_DC_CPDReqEnergyTransferModeType: TargetSOC\r\n\r\n",
          "type": "integer",
          "minimum": 0.0,
          "maximum": 100.0
        },
        "customData": {
          "$ref": "#/definitions/CustomDataType"
        }
      }
    },
    "CustomDataType": {
      "description": "This class does not get 'AdditionalProperties = false' in the schema generation, so it can be extended with arbitrary JSON properties to allow adding custom data.",
      "javaType": "CustomData",
      "type": "object",
      "properties": {
        "vendorId": {
          "type": "string",
          "maxLength": 255
        }
      },
      "required": [
        "vendorId"
      ]
    }
  },
  "type": "object",
  "additionalProperties": false,
  "properties": {
    "evseId": {
      "description": "Defines the EVSE and connector to which the EV is connected. EvseId may not be 0.\r\n",
      "type": "integer",
      "minimum": 1.0
    },
    "maxScheduleTuples": {
      "description": "Contains the maximum elements the EV supports for: +\r\n- ISO 15118-2: schedule tuples in SASchedule (both Pmax and Tariff). +\r\n- ISO 15118-20: PowerScheduleEntry, PriceRule and PriceLevelScheduleEntries.\r\n",
      "type": "integer",
      "minimum": 0.0
    },
    "chargingNeeds": {
      "$ref": "#/definitions/ChargingNeedsType"
    },
    "timestamp": {
      "description": "*(2.1)* Time when EV charging needs were received. +\r\nField can be added when charging station was offline when charging needs were received.\r\n\r\n",
      "type": "string",
      "format": "date-time"
    },
    "customData": {
      "$ref": "#/definitions/CustomDataType"
    }
  },
  "required": [
    "evseId",
    "chargingNeeds"
  ]
}

Response

FeldTypEinschränkungen / Beschreibung
statusstringPflichtenum: Accepted, Rejected, Processing, NoChargingProfile
Returns whether the CSMS has been able to process the message successfully. It does not imply that the evChargingNeeds can be met with the current charging profile.
statusInfoobjectElement providing more information about the status.
statusInfo.reasonCodestringPflichtmaxLength 20
A predefined code for the reason why the status is returned in this response. The string is case-insensitive.
statusInfo.additionalInfostringmaxLength 1024
Additional text to provide detailed information.
JSON-Schema (Response)
{
  "$schema": "http://json-schema.org/draft-06/schema#",
  "$id": "urn:OCPP:Cp:2:2025:1:NotifyEVChargingNeedsResponse",
  "comment": "OCPP 2.1 Edition 1 (c) OCA, Creative Commons Attribution-NoDerivatives 4.0 International Public License",
  "definitions": {
    "NotifyEVChargingNeedsStatusEnumType": {
      "description": "Returns whether the CSMS has been able to process the message successfully. It does not imply that the evChargingNeeds can be met with the current charging profile.\r\n",
      "javaType": "NotifyEVChargingNeedsStatusEnum",
      "type": "string",
      "additionalProperties": false,
      "enum": [
        "Accepted",
        "Rejected",
        "Processing",
        "NoChargingProfile"
      ]
    },
    "StatusInfoType": {
      "description": "Element providing more information about the status.\r\n",
      "javaType": "StatusInfo",
      "type": "object",
      "additionalProperties": false,
      "properties": {
        "reasonCode": {
          "description": "A predefined code for the reason why the status is returned in this response. The string is case-insensitive.\r\n",
          "type": "string",
          "maxLength": 20
        },
        "additionalInfo": {
          "description": "Additional text to provide detailed information.\r\n",
          "type": "string",
          "maxLength": 1024
        },
        "customData": {
          "$ref": "#/definitions/CustomDataType"
        }
      },
      "required": [
        "reasonCode"
      ]
    },
    "CustomDataType": {
      "description": "This class does not get 'AdditionalProperties = false' in the schema generation, so it can be extended with arbitrary JSON properties to allow adding custom data.",
      "javaType": "CustomData",
      "type": "object",
      "properties": {
        "vendorId": {
          "type": "string",
          "maxLength": 255
        }
      },
      "required": [
        "vendorId"
      ]
    }
  },
  "type": "object",
  "additionalProperties": false,
  "properties": {
    "status": {
      "$ref": "#/definitions/NotifyEVChargingNeedsStatusEnumType"
    },
    "statusInfo": {
      "$ref": "#/definitions/StatusInfoType"
    },
    "customData": {
      "$ref": "#/definitions/CustomDataType"
    }
  },
  "required": [
    "status"
  ]
}

Quelle: Open Charge Alliance, OCPP 2.1 – JSON-Schemas, unverändert wiedergegeben. © Open Charge Alliance. Lizenz: CC BY-ND 4.0. Die vollständige Spezifikation gibt es bei der Open Charge Alliance. ocpp-sim ist nicht mit der OCA verbunden.