Docs › OCPP 2.1 › SetDERControl

SetDERControl OCPP 2.1

Der Simulator antwortet mit NotSupported, prüft die Nachricht aber gegen das Schema.

Request

FeldTypEinschränkungen / Beschreibung
isDefaultbooleanPflichtTrue if this is a default DER control
controlIdstringPflichtmaxLength 36
Unique id of this control, e.g. UUID
controlTypestringPflichtenum: EnterService, FreqDroop, FreqWatt, FixedPFAbsorb, FixedPFInject, FixedVar, Gradients, HFMustTrip, HFMayTrip, HVMustTrip, HVMomCess, HVMayTrip, LimitMaxDischarge, LFMustTrip, LVMustTrip, LVMomCess, LVMayTrip, PowerMonitoringMustTrip, VoltVar, VoltWatt, WattPF, WattVar
Type of control. Determines which setting field below is used.
curveobject
curve.curveDataarray<object>PflichtminItems 1; maxItems 10
curve.curveData[].xnumberPflichtThe data value of the X-axis (independent) variable, depending on the curve type.
curve.curveData[].ynumberPflichtThe data value of the Y-axis (dependent) variable, depending on the &lt;&lt;cmn_derunitenumtype&gt;&gt; of the curve. If _y_ is power factor, then a positive value means DER is absorbing reactive power (under-excited), a negative value when DER is injecting reactive power (over-excited).
curve.hysteresisobject
curve.hysteresis.hysteresisHighnumberHigh value for return to normal operation after a grid event, in absolute value. This value adopts the same unit as defined by yUnit
curve.hysteresis.hysteresisLownumberLow value for return to normal operation after a grid event, in absolute value. This value adopts the same unit as defined by yUnit
curve.hysteresis.hysteresisDelaynumberDelay in seconds, once grid parameter within HysteresisLow and HysteresisHigh, for the EV to return to normal operation after a grid event.
curve.hysteresis.hysteresisGradientnumberSet default rate of change (ramp rate %/s) for the EV to return to normal operation after a grid event
curve.priorityintegerPflichtminimum 0.0
Priority of curve (0=highest)
curve.reactivePowerParamsobject
curve.reactivePowerParams.vRefnumberOnly for VoltVar curve: The nominal ac voltage (rms) adjustment to the voltage curve points for Volt-Var curves (percentage).
curve.reactivePowerParams.autonomousVRefEnablebooleanOnly for VoltVar: Enable/disable autonomous VRef adjustment
curve.reactivePowerParams.autonomousVRefTimeConstantnumberOnly for VoltVar: Adjustment range for VRef time constant
curve.voltageParamsobject
curve.voltageParams.hv10MinMeanValuenumberEN 50549-1 chapter 4.9.3.4 Voltage threshold for the 10 min time window mean value monitoring. The 10 min mean is recalculated up to every 3 s. If the present voltage is above this threshold for more than the time defined by _hv10MinMeanValue_, the EV must trip. This value is mandatory if _hv10MinMeanTripDelay_ is set.
curve.voltageParams.hv10MinMeanTripDelaynumberTime for which the voltage is allowed to stay above the 10 min mean value. After this time, the EV must trip. This value is mandatory if OverVoltageMeanValue10min is set.
curve.voltageParams.powerDuringCessationstringenum: Active, Reactive
Parameter is only sent, if the EV has to feed-in power or reactive power during fault-ride through (FRT) as defined by HVMomCess curve and LVMomCess curve.
curve.yUnitstringPflichtenum: Not_Applicable, PctMaxW, PctMaxVar, PctWAvail, PctVarAvail, PctEffectiveV
Unit of the setpoint.
curve.responseTimenumberOpen loop response time, the time to ramp up to 90% of the new target in response to the change in voltage, in seconds. A value of 0 is used to mean no limit. When not present, the device should follow its default behavior.
curve.startTimestringformat date-time
Point in time when this curve will become activated. Only absent when _default_ is true.
curve.durationnumberDuration in seconds that this curve will be active. Only absent when _default_ is true.
enterServiceobject
enterService.priorityintegerPflichtminimum 0.0
Priority of setting (0=highest)
enterService.highVoltagenumberPflichtEnter service voltage high
enterService.lowVoltagenumberPflichtEnter service voltage low
enterService.highFreqnumberPflichtEnter service frequency high
enterService.lowFreqnumberPflichtEnter service frequency low
enterService.delaynumberEnter service delay
enterService.randomDelaynumberEnter service randomized delay
enterService.rampRatenumberEnter service ramp rate in seconds
fixedPFAbsorbobject
fixedPFAbsorb.priorityintegerPflichtminimum 0.0
Priority of setting (0=highest)
fixedPFAbsorb.displacementnumberPflichtPower factor, cos(phi), as value between 0..1.
fixedPFAbsorb.excitationbooleanPflichtTrue when absorbing reactive power (under-excited), false when injecting reactive power (over-excited).
fixedPFAbsorb.startTimestringformat date-time
Time when this setting becomes active
fixedPFAbsorb.durationnumberDuration in seconds that this setting is active.
fixedPFInjectobject
fixedPFInject.priorityintegerPflichtminimum 0.0
Priority of setting (0=highest)
fixedPFInject.displacementnumberPflichtPower factor, cos(phi), as value between 0..1.
fixedPFInject.excitationbooleanPflichtTrue when absorbing reactive power (under-excited), false when injecting reactive power (over-excited).
fixedPFInject.startTimestringformat date-time
Time when this setting becomes active
fixedPFInject.durationnumberDuration in seconds that this setting is active.
fixedVarobject
fixedVar.priorityintegerPflichtminimum 0.0
Priority of setting (0=highest)
fixedVar.setpointnumberPflichtThe value specifies a target var output interpreted as a signed percentage (-100 to 100). A negative value refers to charging, whereas a positive one refers to discharging. The value type is determined by the unit field.
fixedVar.unitstringPflichtenum: Not_Applicable, PctMaxW, PctMaxVar, PctWAvail, PctVarAvail, PctEffectiveV
Unit of the setpoint.
fixedVar.startTimestringformat date-time
Time when this setting becomes active.
fixedVar.durationnumberDuration in seconds that this setting is active.
freqDroopobject
freqDroop.priorityintegerPflichtminimum 0.0
Priority of setting (0=highest)
freqDroop.overFreqnumberPflichtOver-frequency start of droop
freqDroop.underFreqnumberPflichtUnder-frequency start of droop
freqDroop.overDroopnumberPflichtOver-frequency droop per unit, oFDroop
freqDroop.underDroopnumberPflichtUnder-frequency droop per unit, uFDroop
freqDroop.responseTimenumberPflichtOpen loop response time in seconds
freqDroop.startTimestringformat date-time
Time when this setting becomes active
freqDroop.durationnumberDuration in seconds that this setting is active
gradientobject
gradient.priorityintegerPflichtminimum 0.0
Id of setting
gradient.gradientnumberPflichtDefault ramp rate in seconds (0 if not applicable)
gradient.softGradientnumberPflichtSoft-start ramp rate in seconds (0 if not applicable)
limitMaxDischargeobject
limitMaxDischarge.priorityintegerPflichtminimum 0.0
Priority of setting (0=highest)
limitMaxDischarge.pctMaxDischargePowernumberOnly for PowerMonitoring. + The value specifies a percentage (0 to 100) of the rated maximum discharge power of EV. The PowerMonitoring curve becomes active when power exceeds this percentage.
limitMaxDischarge.powerMonitoringMustTripobject
limitMaxDischarge.powerMonitoringMustTrip.curveDataarray<object>PflichtminItems 1; maxItems 10
limitMaxDischarge.powerMonitoringMustTrip.curveData[].xnumberPflichtThe data value of the X-axis (independent) variable, depending on the curve type.
limitMaxDischarge.powerMonitoringMustTrip.curveData[].ynumberPflichtThe data value of the Y-axis (dependent) variable, depending on the &lt;&lt;cmn_derunitenumtype&gt;&gt; of the curve. If _y_ is power factor, then a positive value means DER is absorbing reactive power (under-excited), a negative value when DER is injecting reactive power (over-excited).
limitMaxDischarge.powerMonitoringMustTrip.hysteresisobject
limitMaxDischarge.powerMonitoringMustTrip.hysteresis.hysteresisHighnumberHigh value for return to normal operation after a grid event, in absolute value. This value adopts the same unit as defined by yUnit
limitMaxDischarge.powerMonitoringMustTrip.hysteresis.hysteresisLownumberLow value for return to normal operation after a grid event, in absolute value. This value adopts the same unit as defined by yUnit
limitMaxDischarge.powerMonitoringMustTrip.hysteresis.hysteresisDelaynumberDelay in seconds, once grid parameter within HysteresisLow and HysteresisHigh, for the EV to return to normal operation after a grid event.
limitMaxDischarge.powerMonitoringMustTrip.hysteresis.hysteresisGradientnumberSet default rate of change (ramp rate %/s) for the EV to return to normal operation after a grid event
limitMaxDischarge.powerMonitoringMustTrip.priorityintegerPflichtminimum 0.0
Priority of curve (0=highest)
limitMaxDischarge.powerMonitoringMustTrip.reactivePowerParamsobject
limitMaxDischarge.powerMonitoringMustTrip.reactivePowerParams.vRefnumberOnly for VoltVar curve: The nominal ac voltage (rms) adjustment to the voltage curve points for Volt-Var curves (percentage).
limitMaxDischarge.powerMonitoringMustTrip.reactivePowerParams.autonomousVRefEnablebooleanOnly for VoltVar: Enable/disable autonomous VRef adjustment
limitMaxDischarge.powerMonitoringMustTrip.reactivePowerParams.autonomousVRefTimeConstantnumberOnly for VoltVar: Adjustment range for VRef time constant
limitMaxDischarge.powerMonitoringMustTrip.voltageParamsobject
limitMaxDischarge.powerMonitoringMustTrip.voltageParams.hv10MinMeanValuenumberEN 50549-1 chapter 4.9.3.4 Voltage threshold for the 10 min time window mean value monitoring. The 10 min mean is recalculated up to every 3 s. If the present voltage is above this threshold for more than the time defined by _hv10MinMeanValue_, the EV must trip. This value is mandatory if _hv10MinMeanTripDelay_ is set.
limitMaxDischarge.powerMonitoringMustTrip.voltageParams.hv10MinMeanTripDelaynumberTime for which the voltage is allowed to stay above the 10 min mean value. After this time, the EV must trip. This value is mandatory if OverVoltageMeanValue10min is set.
limitMaxDischarge.powerMonitoringMustTrip.voltageParams.powerDuringCessationstringenum: Active, Reactive
Parameter is only sent, if the EV has to feed-in power or reactive power during fault-ride through (FRT) as defined by HVMomCess curve and LVMomCess curve.
limitMaxDischarge.powerMonitoringMustTrip.yUnitstringPflichtenum: Not_Applicable, PctMaxW, PctMaxVar, PctWAvail, PctVarAvail, PctEffectiveV
Unit of the setpoint.
limitMaxDischarge.powerMonitoringMustTrip.responseTimenumberOpen loop response time, the time to ramp up to 90% of the new target in response to the change in voltage, in seconds. A value of 0 is used to mean no limit. When not present, the device should follow its default behavior.
limitMaxDischarge.powerMonitoringMustTrip.startTimestringformat date-time
Point in time when this curve will become activated. Only absent when _default_ is true.
limitMaxDischarge.powerMonitoringMustTrip.durationnumberDuration in seconds that this curve will be active. Only absent when _default_ is true.
limitMaxDischarge.startTimestringformat date-time
Time when this setting becomes active
limitMaxDischarge.durationnumberDuration in seconds that this setting is active
JSON-Schema (Request)
{
  "$schema": "http://json-schema.org/draft-06/schema#",
  "$id": "urn:OCPP:Cp:2:2025:1:SetDERControlRequest",
  "comment": "OCPP 2.1 Edition 1 (c) OCA, Creative Commons Attribution-NoDerivatives 4.0 International Public License",
  "definitions": {
    "DERControlEnumType": {
      "description": "Type of control.  Determines which setting field below is used.\r\n\r\n",
      "javaType": "DERControlEnum",
      "type": "string",
      "additionalProperties": false,
      "enum": [
        "EnterService",
        "FreqDroop",
        "FreqWatt",
        "FixedPFAbsorb",
        "FixedPFInject",
        "FixedVar",
        "Gradients",
        "HFMustTrip",
        "HFMayTrip",
        "HVMustTrip",
        "HVMomCess",
        "HVMayTrip",
        "LimitMaxDischarge",
        "LFMustTrip",
        "LVMustTrip",
        "LVMomCess",
        "LVMayTrip",
        "PowerMonitoringMustTrip",
        "VoltVar",
        "VoltWatt",
        "WattPF",
        "WattVar"
      ]
    },
    "DERUnitEnumType": {
      "description": "Unit of the setpoint.\r\n",
      "javaType": "DERUnitEnum",
      "type": "string",
      "additionalProperties": false,
      "enum": [
        "Not_Applicable",
        "PctMaxW",
        "PctMaxVar",
        "PctWAvail",
        "PctVarAvail",
        "PctEffectiveV"
      ]
    },
    "PowerDuringCessationEnumType": {
      "description": "Parameter is only sent, if the EV has to feed-in power or reactive power during fault-ride through (FRT) as defined by HVMomCess curve and LVMomCess curve.\r\n\r\n\r\n",
      "javaType": "PowerDuringCessationEnum",
      "type": "string",
      "additionalProperties": false,
      "enum": [
        "Active",
        "Reactive"
      ]
    },
    "DERCurvePointsType": {
      "javaType": "DERCurvePoints",
      "type": "object",
      "additionalProperties": false,
      "properties": {
        "x": {
          "description": "The data value of the X-axis (independent) variable, depending on the curve type.\r\n\r\n\r\n",
          "type": "number"
        },
        "y": {
          "description": "The data value of the Y-axis (dependent) variable, depending on the  &lt;&lt;cmn_derunitenumtype&gt;&gt; of the curve. If _y_ is power factor, then a positive value means DER is absorbing reactive power (under-excited), a negative value when DER is injecting reactive power (over-excited).\r\n\r\n",
          "type": "number"
        },
        "customData": {
          "$ref": "#/definitions/CustomDataType"
        }
      },
      "required": [
        "x",
        "y"
      ]
    },
    "DERCurveType": {
      "javaType": "DERCurve",
      "type": "object",
      "additionalProperties": false,
      "properties": {
        "curveData": {
          "type": "array",
          "additionalItems": false,
          "items": {
            "$ref": "#/definitions/DERCurvePointsType"
          },
          "minItems": 1,
          "maxItems": 10
        },
        "hysteresis": {
          "$ref": "#/definitions/HysteresisType"
        },
        "priority": {
          "description": "Priority of curve (0=highest)\r\n\r\n\r\n",
          "type": "integer",
          "minimum": 0.0
        },
        "reactivePowerParams": {
          "$ref": "#/definitions/ReactivePowerParamsType"
        },
        "voltageParams": {
          "$ref": "#/definitions/VoltageParamsType"
        },
        "yUnit": {
          "$ref": "#/definitions/DERUnitEnumType"
        },
        "responseTime": {
          "description": "Open loop response time, the time to ramp up to 90% of the new target in response to the change in voltage, in seconds. A value of 0 is used to mean no limit. When not present, the device should follow its default behavior.\r\n\r\n\r\n",
          "type": "number"
        },
        "startTime": {
          "description": "Point in time when this curve will become activated. Only absent when _default_ is true.\r\n\r\n",
          "type": "string",
          "format": "date-time"
        },
        "duration": {
          "description": "Duration in seconds that this curve will be active. Only absent when _default_ is true.\r\n\r\n\r\n",
          "type": "number"
        },
        "customData": {
          "$ref": "#/definitions/CustomDataType"
        }
      },
      "required": [
        "priority",
        "yUnit",
        "curveData"
      ]
    },
    "EnterServiceType": {
      "javaType": "EnterService",
      "type": "object",
      "additionalProperties": false,
      "properties": {
        "priority": {
          "description": "Priority of setting (0=highest)\r\n\r\n",
          "type": "integer",
          "minimum": 0.0
        },
        "highVoltage": {
          "description": "Enter service voltage high\r\n",
          "type": "number"
        },
        "lowVoltage": {
          "description": "Enter service voltage low\r\n\r\n\r\n",
          "type": "number"
        },
        "highFreq": {
          "description": "Enter service frequency high\r\n\r\n",
          "type": "number"
        },
        "lowFreq": {
          "description": "Enter service frequency low\r\n\r\n\r\n",
          "type": "number"
        },
        "delay": {
          "description": "Enter service delay\r\n\r\n\r\n",
          "type": "number"
        },
        "randomDelay": {
          "description": "Enter service randomized delay\r\n\r\n\r\n",
          "type": "number"
        },
        "rampRate": {
          "description": "Enter service ramp rate in seconds\r\n\r\n\r\n",
          "type": "number"
        },
        "customData": {
          "$ref": "#/definitions/CustomDataType"
        }
      },
      "required": [
        "priority",
        "highVoltage",
        "lowVoltage",
        "highFreq",
        "lowFreq"
      ]
    },
    "FixedPFType": {
      "javaType": "FixedPF",
      "type": "object",
      "additionalProperties": false,
      "properties": {
        "priority": {
          "description": "Priority of setting (0=highest)\r\n",
          "type": "integer",
          "minimum": 0.0
        },
        "displacement": {
          "description": "Power factor, cos(phi), as value between 0..1.\r\n",
          "type": "number"
        },
        "excitation": {
          "description": "True when absorbing reactive power (under-excited), false when injecting reactive power (over-excited).\r\n",
          "type": "boolean"
        },
        "startTime": {
          "description": "Time when this setting becomes active\r\n",
          "type": "string",
          "format": "date-time"
        },
        "duration": {
          "description": "Duration in seconds that this setting is active.\r\n",
          "type": "number"
        },
        "customData": {
          "$ref": "#/definitions/CustomDataType"
        }
      },
      "required": [
        "priority",
        "displacement",
        "excitation"
      ]
    },
    "FixedVarType": {
      "javaType": "FixedVar",
      "type": "object",
      "additionalProperties": false,
      "properties": {
        "priority": {
          "description": "Priority of setting (0=highest)\r\n",
          "type": "integer",
          "minimum": 0.0
        },
        "setpoint": {
          "description": "The value specifies a target var output interpreted as a signed percentage (-100 to 100). \r\n    A negative value refers to charging, whereas a positive one refers to discharging.\r\n    The value type is determined by the unit field.\r\n",
          "type": "number"
        },
        "unit": {
          "$ref": "#/definitions/DERUnitEnumType"
        },
        "startTime": {
          "description": "Time when this setting becomes active.\r\n",
          "type": "string",
          "format": "date-time"
        },
        "duration": {
          "description": "Duration in seconds that this setting is active.\r\n",
          "type": "number"
        },
        "customData": {
          "$ref": "#/definitions/CustomDataType"
        }
      },
      "required": [
        "priority",
        "setpoint",
        "unit"
      ]
    },
    "FreqDroopType": {
      "javaType": "FreqDroop",
      "type": "object",
      "additionalProperties": false,
      "properties": {
        "priority": {
          "description": "Priority of setting (0=highest)\r\n\r\n\r\n",
          "type": "integer",
          "minimum": 0.0
        },
        "overFreq": {
          "description": "Over-frequency start of droop\r\n\r\n\r\n",
          "type": "number"
        },
        "underFreq": {
          "description": "Under-frequency start of droop\r\n\r\n\r\n",
          "type": "number"
        },
        "overDroop": {
          "description": "Over-frequency droop per unit, oFDroop\r\n\r\n\r\n",
          "type": "number"
        },
        "underDroop": {
          "description": "Under-frequency droop per unit, uFDroop\r\n\r\n",
          "type": "number"
        },
        "responseTime": {
          "description": "Open loop response time in seconds\r\n\r\n",
          "type": "number"
        },
        "startTime": {
          "description": "Time when this setting becomes active\r\n\r\n\r\n",
          "type": "string",
          "format": "date-time"
        },
        "duration": {
          "description": "Duration in seconds that this setting is active\r\n\r\n\r\n",
          "type": "number"
        },
        "customData": {
          "$ref": "#/definitions/CustomDataType"
        }
      },
      "required": [
        "priority",
        "overFreq",
        "underFreq",
        "overDroop",
        "underDroop",
        "responseTime"
      ]
    },
    "GradientType": {
      "javaType": "Gradient",
      "type": "object",
      "additionalProperties": false,
      "properties": {
        "priority": {
          "description": "Id of setting\r\n\r\n\r\n",
          "type": "integer",
          "minimum": 0.0
        },
        "gradient": {
          "description": "Default ramp rate in seconds (0 if not applicable)\r\n\r\n\r\n",
          "type": "number"
        },
        "softGradient": {
          "description": "Soft-start ramp rate in seconds (0 if not applicable)\r\n\r\n\r\n",
          "type": "number"
        },
        "customData": {
          "$ref": "#/definitions/CustomDataType"
        }
      },
      "required": [
        "priority",
        "gradient",
        "softGradient"
      ]
    },
    "HysteresisType": {
      "javaType": "Hysteresis",
      "type": "object",
      "additionalProperties": false,
      "properties": {
        "hysteresisHigh": {
          "description": "High value for return to normal operation after a grid event, in absolute value. This value adopts the same unit as defined by yUnit\r\n\r\n\r\n",
          "type": "number"
        },
        "hysteresisLow": {
          "description": "Low value for return to normal operation after a grid event, in absolute value. This value adopts the same unit as defined by yUnit\r\n\r\n\r\n",
          "type": "number"
        },
        "hysteresisDelay": {
          "description": "Delay in seconds, once grid parameter within HysteresisLow and HysteresisHigh, for the EV to return to normal operation after a grid event.\r\n\r\n\r\n",
          "type": "number"
        },
        "hysteresisGradient": {
          "description": "Set default rate of change (ramp rate %/s) for the EV to return to normal operation after a grid event\r\n\r\n\r\n",
          "type": "number"
        },
        "customData": {
          "$ref": "#/definitions/CustomDataType"
        }
      }
    },
    "LimitMaxDischargeType": {
      "javaType": "LimitMaxDischarge",
      "type": "object",
      "additionalProperties": false,
      "properties": {
        "priority": {
          "description": "Priority of setting (0=highest)\r\n\r\n\r\n",
          "type": "integer",
          "minimum": 0.0
        },
        "pctMaxDischargePower": {
          "description": "Only for PowerMonitoring. +\r\n    The value specifies a percentage (0 to 100) of the rated maximum discharge power of EV. \r\n    The PowerMonitoring curve becomes active when power exceeds this percentage.\r\n\r\n\r\n",
          "type": "number"
        },
        "powerMonitoringMustTrip": {
          "$ref": "#/definitions/DERCurveType"
        },
        "startTime": {
          "description": "Time when this setting becomes active\r\n\r\n\r\n",
          "type": "string",
          "format": "date-time"
        },
        "duration": {
          "description": "Duration in seconds that this setting is active\r\n\r\n\r\n",
          "type": "number"
        },
        "customData": {
          "$ref": "#/definitions/CustomDataType"
        }
      },
      "required": [
        "priority"
      ]
    },
    "ReactivePowerParamsType": {
      "javaType": "ReactivePowerParams",
      "type": "object",
      "additionalProperties": false,
      "properties": {
        "vRef": {
          "description": "Only for VoltVar curve: The nominal ac voltage (rms) adjustment to the voltage curve points for Volt-Var curves (percentage).\r\n\r\n\r\n",
          "type": "number"
        },
        "autonomousVRefEnable": {
          "description": "Only for VoltVar: Enable/disable autonomous VRef adjustment\r\n\r\n\r\n",
          "type": "boolean"
        },
        "autonomousVRefTimeConstant": {
          "description": "Only for VoltVar: Adjustment range for VRef time constant\r\n\r\n\r\n",
          "type": "number"
        },
        "customData": {
          "$ref": "#/definitions/CustomDataType"
        }
      }
    },
    "VoltageParamsType": {
      "javaType": "VoltageParams",
      "type": "object",
      "additionalProperties": false,
      "properties": {
        "hv10MinMeanValue": {
          "description": "EN 50549-1 chapter 4.9.3.4\r\n    Voltage threshold for the 10 min time window mean value monitoring.\r\n    The 10 min mean is recalculated up to every 3 s. \r\n    If the present voltage is above this threshold for more than the time defined by _hv10MinMeanValue_, the EV must trip.\r\n    This value is mandatory if _hv10MinMeanTripDelay_ is set.\r\n\r\n\r\n",
          "type": "number"
        },
        "hv10MinMeanTripDelay": {
          "description": "Time for which the voltage is allowed to stay above the 10 min mean value. \r\n    After this time, the EV must trip.\r\n    This value is mandatory if OverVoltageMeanValue10min is set.\r\n\r\n\r\n",
          "type": "number"
        },
        "powerDuringCessation": {
          "$ref": "#/definitions/PowerDuringCessationEnumType"
        },
        "customData": {
          "$ref": "#/definitions/CustomDataType"
        }
      }
    },
    "CustomDataType": {
      "description": "This class does not get 'AdditionalProperties = false' in the schema generation, so it can be extended with arbitrary JSON properties to allow adding custom data.",
      "javaType": "CustomData",
      "type": "object",
      "properties": {
        "vendorId": {
          "type": "string",
          "maxLength": 255
        }
      },
      "required": [
        "vendorId"
      ]
    }
  },
  "type": "object",
  "additionalProperties": false,
  "properties": {
    "isDefault": {
      "description": "True if this is a default DER control\r\n\r\n",
      "type": "boolean"
    },
    "controlId": {
      "description": "Unique id of this control, e.g. UUID\r\n\r\n",
      "type": "string",
      "maxLength": 36
    },
    "controlType": {
      "$ref": "#/definitions/DERControlEnumType"
    },
    "curve": {
      "$ref": "#/definitions/DERCurveType"
    },
    "enterService": {
      "$ref": "#/definitions/EnterServiceType"
    },
    "fixedPFAbsorb": {
      "$ref": "#/definitions/FixedPFType"
    },
    "fixedPFInject": {
      "$ref": "#/definitions/FixedPFType"
    },
    "fixedVar": {
      "$ref": "#/definitions/FixedVarType"
    },
    "freqDroop": {
      "$ref": "#/definitions/FreqDroopType"
    },
    "gradient": {
      "$ref": "#/definitions/GradientType"
    },
    "limitMaxDischarge": {
      "$ref": "#/definitions/LimitMaxDischargeType"
    },
    "customData": {
      "$ref": "#/definitions/CustomDataType"
    }
  },
  "required": [
    "isDefault",
    "controlId",
    "controlType"
  ]
}

Response

FeldTypEinschränkungen / Beschreibung
statusstringPflichtenum: Accepted, Rejected, NotSupported, NotFound
Result of operation.
statusInfoobjectElement providing more information about the status.
statusInfo.reasonCodestringPflichtmaxLength 20
A predefined code for the reason why the status is returned in this response. The string is case-insensitive.
statusInfo.additionalInfostringmaxLength 1024
Additional text to provide detailed information.
supersededIdsarray<string>maxLength 36; minItems 1; maxItems 24
List of controlIds that are superseded as a result of setting this control.
JSON-Schema (Response)
{
  "$schema": "http://json-schema.org/draft-06/schema#",
  "$id": "urn:OCPP:Cp:2:2025:1:SetDERControlResponse",
  "comment": "OCPP 2.1 Edition 1 (c) OCA, Creative Commons Attribution-NoDerivatives 4.0 International Public License",
  "definitions": {
    "DERControlStatusEnumType": {
      "description": "Result of operation.\r\n\r\n",
      "javaType": "DERControlStatusEnum",
      "type": "string",
      "additionalProperties": false,
      "enum": [
        "Accepted",
        "Rejected",
        "NotSupported",
        "NotFound"
      ]
    },
    "StatusInfoType": {
      "description": "Element providing more information about the status.\r\n",
      "javaType": "StatusInfo",
      "type": "object",
      "additionalProperties": false,
      "properties": {
        "reasonCode": {
          "description": "A predefined code for the reason why the status is returned in this response. The string is case-insensitive.\r\n",
          "type": "string",
          "maxLength": 20
        },
        "additionalInfo": {
          "description": "Additional text to provide detailed information.\r\n",
          "type": "string",
          "maxLength": 1024
        },
        "customData": {
          "$ref": "#/definitions/CustomDataType"
        }
      },
      "required": [
        "reasonCode"
      ]
    },
    "CustomDataType": {
      "description": "This class does not get 'AdditionalProperties = false' in the schema generation, so it can be extended with arbitrary JSON properties to allow adding custom data.",
      "javaType": "CustomData",
      "type": "object",
      "properties": {
        "vendorId": {
          "type": "string",
          "maxLength": 255
        }
      },
      "required": [
        "vendorId"
      ]
    }
  },
  "type": "object",
  "additionalProperties": false,
  "properties": {
    "status": {
      "$ref": "#/definitions/DERControlStatusEnumType"
    },
    "statusInfo": {
      "$ref": "#/definitions/StatusInfoType"
    },
    "supersededIds": {
      "description": "List of controlIds that are superseded as a result of setting this control.\r\n",
      "type": "array",
      "additionalItems": false,
      "items": {
        "type": "string",
        "maxLength": 36
      },
      "minItems": 1,
      "maxItems": 24
    },
    "customData": {
      "$ref": "#/definitions/CustomDataType"
    }
  },
  "required": [
    "status"
  ]
}

Quelle: Open Charge Alliance, OCPP 2.1 – JSON-Schemas, unverändert wiedergegeben. © Open Charge Alliance. Lizenz: CC BY-ND 4.0. Die vollständige Spezifikation gibt es bei der Open Charge Alliance. ocpp-sim ist nicht mit der OCA verbunden.