NotifyMonitoringReport OCPP 2.0.1
Der Simulator antwortet mit NotSupported, prüft die Nachricht aber gegen das Schema.
Auch in: OCPP 2.1
Request
| Feld | Typ | Einschränkungen / Beschreibung | |
|---|---|---|---|
monitor | array<object> | minItems 1 | |
monitor[].component | object | Pflicht | A physical or logical component |
monitor[].component.evse | object | EVSE urn:x-oca:ocpp:uid:2:233123 Electric Vehicle Supply Equipment | |
monitor[].component.evse.id | integer | Pflicht | Identified_ Object. MRID. Numeric_ Identifier urn:x-enexis:ecdm:uid:1:569198 EVSE Identifier. This contains a number (> 0) designating an EVSE of the Charging Station. |
monitor[].component.evse.connectorId | integer | An id to designate a specific connector (on an EVSE) by connector index number. | |
monitor[].component.name | string | Pflicht | maxLength 50 Name of the component. Name should be taken from the list of standardized component names whenever possible. Case Insensitive. strongly advised to use Camel Case. |
monitor[].component.instance | string | maxLength 50 Name of instance in case the component exists as multiple instances. Case Insensitive. strongly advised to use Camel Case. | |
monitor[].variable | object | Pflicht | Reference key to a component-variable. |
monitor[].variable.name | string | Pflicht | maxLength 50 Name of the variable. Name should be taken from the list of standardized variable names whenever possible. Case Insensitive. strongly advised to use Camel Case. |
monitor[].variable.instance | string | maxLength 50 Name of instance in case the variable exists as multiple instances. Case Insensitive. strongly advised to use Camel Case. | |
monitor[].variableMonitoring | array<object> | Pflicht | minItems 1 |
monitor[].variableMonitoring[].id | integer | Pflicht | Identifies the monitor. |
monitor[].variableMonitoring[].transaction | boolean | Pflicht | Monitor only active when a transaction is ongoing on a component relevant to this transaction. |
monitor[].variableMonitoring[].value | number | Pflicht | Value for threshold or delta monitoring. For Periodic or PeriodicClockAligned this is the interval in seconds. |
monitor[].variableMonitoring[].type | string | Pflicht | enum: UpperThreshold, LowerThreshold, Delta, Periodic, PeriodicClockAligned The type of this monitor, e.g. a threshold, delta or periodic monitor. |
monitor[].variableMonitoring[].severity | integer | Pflicht | The severity that will be assigned to an event that is triggered by this monitor. The severity range is 0-9, with 0 as the highest and 9 as the lowest severity level. The severity levels have the following meaning: + *0-Danger* + Indicates lives are potentially in danger. Urgent attention is needed and action should be taken immediately. + *1-Hardware Failure* + Indicates that the Charging Station is unable to continue regular operations due to Hardware issues. Action is required. + *2-System Failure* + Indicates that the Charging Station is unable to continue regular operations due to software or minor hardware issues. Action is required. + *3-Critical* + Indicates a critical error. Action is required. + *4-Error* + Indicates a non-urgent error. Action is required. + *5-Alert* + Indicates an alert event. Default severity for any type of monitoring event. + *6-Warning* + Indicates a warning event. Action may be required. + *7-Notice* + Indicates an unusual event. No immediate action is required. + *8-Informational* + Indicates a regular operational event. May be used for reporting, measuring throughput, etc. No action is required. + *9-Debug* + Indicates information useful to developers for debugging, not useful during operations. |
requestId | integer | Pflicht | The id of the GetMonitoringRequest that requested this report. |
tbc | boolean | “to be continued” indicator. Indicates whether another part of the monitoringData follows in an upcoming notifyMonitoringReportRequest message. Default value when omitted is false. | |
seqNo | integer | Pflicht | Sequence number of this message. First message starts at 0. |
generatedAt | string | Pflicht | format date-time Timestamp of the moment this message was generated at the Charging Station. |
JSON-Schema (Request)
{
"$schema": "http://json-schema.org/draft-06/schema#",
"comment": "OCPP 2.0.1 FINAL",
"definitions": {
"CustomDataType": {
"description": "This class does not get 'AdditionalProperties = false' in the schema generation, so it can be extended with arbitrary JSON properties to allow adding custom data.",
"javaType": "CustomData",
"type": "object",
"properties": {
"vendorId": {
"type": "string",
"maxLength": 255
}
},
"required": [
"vendorId"
]
},
"MonitorEnumType": {
"description": "The type of this monitor, e.g. a threshold, delta or periodic monitor. \r\n",
"javaType": "MonitorEnum",
"type": "string",
"additionalProperties": false,
"enum": [
"UpperThreshold",
"LowerThreshold",
"Delta",
"Periodic",
"PeriodicClockAligned"
]
},
"ComponentType": {
"description": "A physical or logical component\r\n",
"javaType": "Component",
"type": "object",
"additionalProperties": false,
"properties": {
"customData": {
"$ref": "#/definitions/CustomDataType"
},
"evse": {
"$ref": "#/definitions/EVSEType"
},
"name": {
"description": "Name of the component. Name should be taken from the list of standardized component names whenever possible. Case Insensitive. strongly advised to use Camel Case.\r\n",
"type": "string",
"maxLength": 50
},
"instance": {
"description": "Name of instance in case the component exists as multiple instances. Case Insensitive. strongly advised to use Camel Case.\r\n",
"type": "string",
"maxLength": 50
}
},
"required": [
"name"
]
},
"EVSEType": {
"description": "EVSE\r\nurn:x-oca:ocpp:uid:2:233123\r\nElectric Vehicle Supply Equipment\r\n",
"javaType": "EVSE",
"type": "object",
"additionalProperties": false,
"properties": {
"customData": {
"$ref": "#/definitions/CustomDataType"
},
"id": {
"description": "Identified_ Object. MRID. Numeric_ Identifier\r\nurn:x-enexis:ecdm:uid:1:569198\r\nEVSE Identifier. This contains a number (> 0) designating an EVSE of the Charging Station.\r\n",
"type": "integer"
},
"connectorId": {
"description": "An id to designate a specific connector (on an EVSE) by connector index number.\r\n",
"type": "integer"
}
},
"required": [
"id"
]
},
"MonitoringDataType": {
"description": "Class to hold parameters of SetVariableMonitoring request.\r\n",
"javaType": "MonitoringData",
"type": "object",
"additionalProperties": false,
"properties": {
"customData": {
"$ref": "#/definitions/CustomDataType"
},
"component": {
"$ref": "#/definitions/ComponentType"
},
"variable": {
"$ref": "#/definitions/VariableType"
},
"variableMonitoring": {
"type": "array",
"additionalItems": false,
"items": {
"$ref": "#/definitions/VariableMonitoringType"
},
"minItems": 1
}
},
"required": [
"component",
"variable",
"variableMonitoring"
]
},
"VariableMonitoringType": {
"description": "A monitoring setting for a variable.\r\n",
"javaType": "VariableMonitoring",
"type": "object",
"additionalProperties": false,
"properties": {
"customData": {
"$ref": "#/definitions/CustomDataType"
},
"id": {
"description": "Identifies the monitor.\r\n",
"type": "integer"
},
"transaction": {
"description": "Monitor only active when a transaction is ongoing on a component relevant to this transaction. \r\n",
"type": "boolean"
},
"value": {
"description": "Value for threshold or delta monitoring.\r\nFor Periodic or PeriodicClockAligned this is the interval in seconds.\r\n",
"type": "number"
},
"type": {
"$ref": "#/definitions/MonitorEnumType"
},
"severity": {
"description": "The severity that will be assigned to an event that is triggered by this monitor. The severity range is 0-9, with 0 as the highest and 9 as the lowest severity level.\r\n\r\nThe severity levels have the following meaning: +\r\n*0-Danger* +\r\nIndicates lives are potentially in danger. Urgent attention is needed and action should be taken immediately. +\r\n*1-Hardware Failure* +\r\nIndicates that the Charging Station is unable to continue regular operations due to Hardware issues. Action is required. +\r\n*2-System Failure* +\r\nIndicates that the Charging Station is unable to continue regular operations due to software or minor hardware issues. Action is required. +\r\n*3-Critical* +\r\nIndicates a critical error. Action is required. +\r\n*4-Error* +\r\nIndicates a non-urgent error. Action is required. +\r\n*5-Alert* +\r\nIndicates an alert event. Default severity for any type of monitoring event. +\r\n*6-Warning* +\r\nIndicates a warning event. Action may be required. +\r\n*7-Notice* +\r\nIndicates an unusual event. No immediate action is required. +\r\n*8-Informational* +\r\nIndicates a regular operational event. May be used for reporting, measuring throughput, etc. No action is required. +\r\n*9-Debug* +\r\nIndicates information useful to developers for debugging, not useful during operations.\r\n",
"type": "integer"
}
},
"required": [
"id",
"transaction",
"value",
"type",
"severity"
]
},
"VariableType": {
"description": "Reference key to a component-variable.\r\n",
"javaType": "Variable",
"type": "object",
"additionalProperties": false,
"properties": {
"customData": {
"$ref": "#/definitions/CustomDataType"
},
"name": {
"description": "Name of the variable. Name should be taken from the list of standardized variable names whenever possible. Case Insensitive. strongly advised to use Camel Case.\r\n",
"type": "string",
"maxLength": 50
},
"instance": {
"description": "Name of instance in case the variable exists as multiple instances. Case Insensitive. strongly advised to use Camel Case.\r\n",
"type": "string",
"maxLength": 50
}
},
"required": [
"name"
]
}
},
"type": "object",
"additionalProperties": false,
"properties": {
"customData": {
"$ref": "#/definitions/CustomDataType"
},
"monitor": {
"type": "array",
"additionalItems": false,
"items": {
"$ref": "#/definitions/MonitoringDataType"
},
"minItems": 1
},
"requestId": {
"description": "The id of the GetMonitoringRequest that requested this report.\r\n\r\n",
"type": "integer"
},
"tbc": {
"description": "“to be continued” indicator. Indicates whether another part of the monitoringData follows in an upcoming notifyMonitoringReportRequest message. Default value when omitted is false.\r\n",
"type": "boolean",
"default": false
},
"seqNo": {
"description": "Sequence number of this message. First message starts at 0.\r\n",
"type": "integer"
},
"generatedAt": {
"description": "Timestamp of the moment this message was generated at the Charging Station.\r\n",
"type": "string",
"format": "date-time"
}
},
"required": [
"requestId",
"seqNo",
"generatedAt"
]
}Response
Leeres Objekt {}.
JSON-Schema (Response)
{
"$schema": "http://json-schema.org/draft-06/schema#",
"comment": "OCPP 2.0.1 FINAL",
"definitions": {
"CustomDataType": {
"description": "This class does not get 'AdditionalProperties = false' in the schema generation, so it can be extended with arbitrary JSON properties to allow adding custom data.",
"javaType": "CustomData",
"type": "object",
"properties": {
"vendorId": {
"type": "string",
"maxLength": 255
}
},
"required": [
"vendorId"
]
}
},
"type": "object",
"additionalProperties": false,
"properties": {
"customData": {
"$ref": "#/definitions/CustomDataType"
}
}
}Quelle: Open Charge Alliance, OCPP 2.0.1 – JSON-Schemas, unverändert wiedergegeben. © Open Charge Alliance. Lizenz: CC BY-ND 4.0. Die vollständige Spezifikation gibt es bei der Open Charge Alliance. ocpp-sim ist nicht mit der OCA verbunden.