Docs › OCPP 2.1 › NotifyMonitoringReport

NotifyMonitoringReport OCPP 2.1

Der Simulator antwortet mit NotSupported, prüft die Nachricht aber gegen das Schema.

Auch in: OCPP 2.0.1

Request

FeldTypEinschränkungen / Beschreibung
monitorarray<object>minItems 1
monitor[].componentobjectPflichtA physical or logical component
monitor[].component.evseobjectElectric Vehicle Supply Equipment
monitor[].component.evse.idintegerPflichtminimum 0.0
EVSE Identifier. This contains a number (&gt; 0) designating an EVSE of the Charging Station.
monitor[].component.evse.connectorIdintegerminimum 0.0
An id to designate a specific connector (on an EVSE) by connector index number.
monitor[].component.namestringPflichtmaxLength 50
Name of the component. Name should be taken from the list of standardized component names whenever possible. Case Insensitive. strongly advised to use Camel Case.
monitor[].component.instancestringmaxLength 50
Name of instance in case the component exists as multiple instances. Case Insensitive. strongly advised to use Camel Case.
monitor[].variableobjectPflichtReference key to a component-variable.
monitor[].variable.namestringPflichtmaxLength 50
Name of the variable. Name should be taken from the list of standardized variable names whenever possible. Case Insensitive. strongly advised to use Camel Case.
monitor[].variable.instancestringmaxLength 50
Name of instance in case the variable exists as multiple instances. Case Insensitive. strongly advised to use Camel Case.
monitor[].variableMonitoringarray<object>PflichtminItems 1
monitor[].variableMonitoring[].idintegerPflichtminimum 0.0
Identifies the monitor.
monitor[].variableMonitoring[].transactionbooleanPflichtMonitor only active when a transaction is ongoing on a component relevant to this transaction.
monitor[].variableMonitoring[].valuenumberPflichtValue for threshold or delta monitoring. For Periodic or PeriodicClockAligned this is the interval in seconds.
monitor[].variableMonitoring[].typestringPflichtenum: UpperThreshold, LowerThreshold, Delta, Periodic, PeriodicClockAligned, TargetDelta, TargetDeltaRelative
The type of this monitor, e.g. a threshold, delta or periodic monitor.
monitor[].variableMonitoring[].severityintegerPflichtminimum 0.0
The severity that will be assigned to an event that is triggered by this monitor. The severity range is 0-9, with 0 as the highest and 9 as the lowest severity level. The severity levels have the following meaning: + *0-Danger* + Indicates lives are potentially in danger. Urgent attention is needed and action should be taken immediately. + *1-Hardware Failure* + Indicates that the Charging Station is unable to continue regular operations due to Hardware issues. Action is required. + *2-System Failure* + Indicates that the Charging Station is unable to continue regular operations due to software or minor hardware issues. Action is required. + *3-Critical* + Indicates a critical error. Action is required. + *4-Error* + Indicates a non-urgent error. Action is required. + *5-Alert* + Indicates an alert event. Default severity for any type of monitoring event. + *6-Warning* + Indicates a warning event. Action may be required. + *7-Notice* + Indicates an unusual event. No immediate action is required. + *8-Informational* + Indicates a regular operational event. May be used for reporting, measuring throughput, etc. No action is required. + *9-Debug* + Indicates information useful to developers for debugging, not useful during operations.
monitor[].variableMonitoring[].eventNotificationTypestringPflichtenum: HardWiredNotification, HardWiredMonitor, PreconfiguredMonitor, CustomMonitor
*(2.1)* Type of monitor.
requestIdintegerPflichtThe id of the GetMonitoringRequest that requested this report.
tbcboolean“to be continued” indicator. Indicates whether another part of the monitoringData follows in an upcoming notifyMonitoringReportRequest message. Default value when omitted is false.
seqNointegerPflichtminimum 0.0
Sequence number of this message. First message starts at 0.
generatedAtstringPflichtformat date-time
Timestamp of the moment this message was generated at the Charging Station.
JSON-Schema (Request)
{
  "$schema": "http://json-schema.org/draft-06/schema#",
  "$id": "urn:OCPP:Cp:2:2025:1:NotifyMonitoringReportRequest",
  "comment": "OCPP 2.1 Edition 1 (c) OCA, Creative Commons Attribution-NoDerivatives 4.0 International Public License",
  "definitions": {
    "EventNotificationEnumType": {
      "description": "*(2.1)* Type of monitor.\r\n",
      "javaType": "EventNotificationEnum",
      "type": "string",
      "additionalProperties": false,
      "enum": [
        "HardWiredNotification",
        "HardWiredMonitor",
        "PreconfiguredMonitor",
        "CustomMonitor"
      ]
    },
    "MonitorEnumType": {
      "description": "The type of this monitor, e.g. a threshold, delta or periodic monitor. \r\n",
      "javaType": "MonitorEnum",
      "type": "string",
      "additionalProperties": false,
      "enum": [
        "UpperThreshold",
        "LowerThreshold",
        "Delta",
        "Periodic",
        "PeriodicClockAligned",
        "TargetDelta",
        "TargetDeltaRelative"
      ]
    },
    "ComponentType": {
      "description": "A physical or logical component\r\n",
      "javaType": "Component",
      "type": "object",
      "additionalProperties": false,
      "properties": {
        "evse": {
          "$ref": "#/definitions/EVSEType"
        },
        "name": {
          "description": "Name of the component. Name should be taken from the list of standardized component names whenever possible. Case Insensitive. strongly advised to use Camel Case.\r\n",
          "type": "string",
          "maxLength": 50
        },
        "instance": {
          "description": "Name of instance in case the component exists as multiple instances. Case Insensitive. strongly advised to use Camel Case.\r\n",
          "type": "string",
          "maxLength": 50
        },
        "customData": {
          "$ref": "#/definitions/CustomDataType"
        }
      },
      "required": [
        "name"
      ]
    },
    "EVSEType": {
      "description": "Electric Vehicle Supply Equipment\r\n",
      "javaType": "EVSE",
      "type": "object",
      "additionalProperties": false,
      "properties": {
        "id": {
          "description": "EVSE Identifier. This contains a number (&gt; 0) designating an EVSE of the Charging Station.\r\n",
          "type": "integer",
          "minimum": 0.0
        },
        "connectorId": {
          "description": "An id to designate a specific connector (on an EVSE) by connector index number.\r\n",
          "type": "integer",
          "minimum": 0.0
        },
        "customData": {
          "$ref": "#/definitions/CustomDataType"
        }
      },
      "required": [
        "id"
      ]
    },
    "MonitoringDataType": {
      "description": "Class to hold parameters of SetVariableMonitoring request.\r\n",
      "javaType": "MonitoringData",
      "type": "object",
      "additionalProperties": false,
      "properties": {
        "component": {
          "$ref": "#/definitions/ComponentType"
        },
        "variable": {
          "$ref": "#/definitions/VariableType"
        },
        "variableMonitoring": {
          "type": "array",
          "additionalItems": false,
          "items": {
            "$ref": "#/definitions/VariableMonitoringType"
          },
          "minItems": 1
        },
        "customData": {
          "$ref": "#/definitions/CustomDataType"
        }
      },
      "required": [
        "component",
        "variable",
        "variableMonitoring"
      ]
    },
    "VariableMonitoringType": {
      "description": "A monitoring setting for a variable.\r\n",
      "javaType": "VariableMonitoring",
      "type": "object",
      "additionalProperties": false,
      "properties": {
        "id": {
          "description": "Identifies the monitor.\r\n",
          "type": "integer",
          "minimum": 0.0
        },
        "transaction": {
          "description": "Monitor only active when a transaction is ongoing on a component relevant to this transaction. \r\n",
          "type": "boolean"
        },
        "value": {
          "description": "Value for threshold or delta monitoring.\r\nFor Periodic or PeriodicClockAligned this is the interval in seconds.\r\n",
          "type": "number"
        },
        "type": {
          "$ref": "#/definitions/MonitorEnumType"
        },
        "severity": {
          "description": "The severity that will be assigned to an event that is triggered by this monitor. The severity range is 0-9, with 0 as the highest and 9 as the lowest severity level.\r\n\r\nThe severity levels have the following meaning: +\r\n*0-Danger* +\r\nIndicates lives are potentially in danger. Urgent attention is needed and action should be taken immediately. +\r\n*1-Hardware Failure* +\r\nIndicates that the Charging Station is unable to continue regular operations due to Hardware issues. Action is required. +\r\n*2-System Failure* +\r\nIndicates that the Charging Station is unable to continue regular operations due to software or minor hardware issues. Action is required. +\r\n*3-Critical* +\r\nIndicates a critical error. Action is required. +\r\n*4-Error* +\r\nIndicates a non-urgent error. Action is required. +\r\n*5-Alert* +\r\nIndicates an alert event. Default severity for any type of monitoring event.  +\r\n*6-Warning* +\r\nIndicates a warning event. Action may be required. +\r\n*7-Notice* +\r\nIndicates an unusual event. No immediate action is required. +\r\n*8-Informational* +\r\nIndicates a regular operational event. May be used for reporting, measuring throughput, etc. No action is required. +\r\n*9-Debug* +\r\nIndicates information useful to developers for debugging, not useful during operations.\r\n",
          "type": "integer",
          "minimum": 0.0
        },
        "eventNotificationType": {
          "$ref": "#/definitions/EventNotificationEnumType"
        },
        "customData": {
          "$ref": "#/definitions/CustomDataType"
        }
      },
      "required": [
        "id",
        "transaction",
        "value",
        "type",
        "severity",
        "eventNotificationType"
      ]
    },
    "VariableType": {
      "description": "Reference key to a component-variable.\r\n",
      "javaType": "Variable",
      "type": "object",
      "additionalProperties": false,
      "properties": {
        "name": {
          "description": "Name of the variable. Name should be taken from the list of standardized variable names whenever possible. Case Insensitive. strongly advised to use Camel Case.\r\n",
          "type": "string",
          "maxLength": 50
        },
        "instance": {
          "description": "Name of instance in case the variable exists as multiple instances. Case Insensitive. strongly advised to use Camel Case.\r\n",
          "type": "string",
          "maxLength": 50
        },
        "customData": {
          "$ref": "#/definitions/CustomDataType"
        }
      },
      "required": [
        "name"
      ]
    },
    "CustomDataType": {
      "description": "This class does not get 'AdditionalProperties = false' in the schema generation, so it can be extended with arbitrary JSON properties to allow adding custom data.",
      "javaType": "CustomData",
      "type": "object",
      "properties": {
        "vendorId": {
          "type": "string",
          "maxLength": 255
        }
      },
      "required": [
        "vendorId"
      ]
    }
  },
  "type": "object",
  "additionalProperties": false,
  "properties": {
    "monitor": {
      "type": "array",
      "additionalItems": false,
      "items": {
        "$ref": "#/definitions/MonitoringDataType"
      },
      "minItems": 1
    },
    "requestId": {
      "description": "The id of the GetMonitoringRequest that requested this report.\r\n\r\n",
      "type": "integer"
    },
    "tbc": {
      "description": "“to be continued” indicator. Indicates whether another part of the monitoringData follows in an upcoming notifyMonitoringReportRequest message. Default value when omitted is false.\r\n",
      "type": "boolean",
      "default": false
    },
    "seqNo": {
      "description": "Sequence number of this message. First message starts at 0.\r\n",
      "type": "integer",
      "minimum": 0.0
    },
    "generatedAt": {
      "description": "Timestamp of the moment this message was generated at the Charging Station.\r\n",
      "type": "string",
      "format": "date-time"
    },
    "customData": {
      "$ref": "#/definitions/CustomDataType"
    }
  },
  "required": [
    "requestId",
    "seqNo",
    "generatedAt"
  ]
}

Response

Leeres Objekt {}.

JSON-Schema (Response)
{
  "$schema": "http://json-schema.org/draft-06/schema#",
  "$id": "urn:OCPP:Cp:2:2025:1:NotifyMonitoringReportResponse",
  "comment": "OCPP 2.1 Edition 1 (c) OCA, Creative Commons Attribution-NoDerivatives 4.0 International Public License",
  "definitions": {
    "CustomDataType": {
      "description": "This class does not get 'AdditionalProperties = false' in the schema generation, so it can be extended with arbitrary JSON properties to allow adding custom data.",
      "javaType": "CustomData",
      "type": "object",
      "properties": {
        "vendorId": {
          "type": "string",
          "maxLength": 255
        }
      },
      "required": [
        "vendorId"
      ]
    }
  },
  "type": "object",
  "additionalProperties": false,
  "properties": {
    "customData": {
      "$ref": "#/definitions/CustomDataType"
    }
  }
}

Quelle: Open Charge Alliance, OCPP 2.1 – JSON-Schemas, unverändert wiedergegeben. © Open Charge Alliance. Lizenz: CC BY-ND 4.0. Die vollständige Spezifikation gibt es bei der Open Charge Alliance. ocpp-sim ist nicht mit der OCA verbunden.